Place (2) fastening supports, with (1) washer
9a
and (1) M6 nut, without tightening.
Connect (2) communication cables (A), the
9b
(2) 4-way boxes and (4) 2-way boxes of the
interior air distribution panel to those of the
Compact.
Bear in mind that the two-way box marked
with white cables is joined to the connector
with white cables that comes out of the central
part of the equipment.
NOTE: It is very important not to invert the
colours of the condenser fan 2-way box
(box with R and N wires).
Introduce the cabling in the gap (H) in the
9c
interior air distribution panel in order not to
interfere in the adjustment of the ducts with
the base of the unit.
Air conditioning for vehicles
9a
M6 nut
9b
A
9c
H