Accessoires; Technical Data - Sennheiser SI 1015 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11

Accessoires

GZL 1019 A1 BNC/BNC co-axial cable
For connecting a radiator to the SI 1015, SI 29-5 or SI 1029 transmitters. Length: 1 m.
GZL 1019 A5 BNC/BNC co-axial cable
For connecting a radiator to the SI 1015, SI 29-5 or SI 1029 transmitters. Length: 5 m.
GZL 1019 A10 BNC/BNC co-axial cable
For connecting a radiator to the SI 1015, SI 29-5 or SI 1029 transmitters. Length: 10 m.
GZV 1019 BNC coupler
for connecting two GZL 1019 A1, -5, -10 co-axial cables.
GA 1031-AM blank module
For 19" rack mounting (with BNC sockets).
GA 1031-CC blank module
For 19" rack mounting.
For the AF connection, use a standard XLR-3 connection cable of the required length.
Note: "IR Planning Brochure" from Sennheiser
Information on the many possible areas of application of Sennheiser infra-red audio transmission
systems can be found in the "IR Planning Brochure". This brochure gives detailed information on
infra-red transmission technology and contains application examples as well as possible product
combinations and overviews for infra-red system planning.
Since we are continually trying to improve our products it may happen that technical alterations
are made on the described products after this manual has gone to press. We apologise for any
inconvenience.
16

Technical Data

SI 1015
Operating voltage
Current consumption
Terminating impedance of the RF outputs
Carrier frequency 1
Carrier frequency 2
Inputs
Input sensitivity
RF outputs
SZI 1015
Number of transmitting diodes
Average radiating power
Wavelength of radiated infra-red light
Carrier frequency range
RF input level
Inputs / outputs
Threshold voltage for
automatic on/off function
Operating voltage
Current consumption
Stand-by
Dimensions in mm
Weight
NT 1015
Mains voltage
Output voltage
Output current
Modulator
24 - 35 V DC (via NT 1015)
< 140 mA
50 Ω
2.3 MHz
2.8 MHz
2 x XLR-3, balanced
50 mV – 5 V
2 x BNC, in parallel with barrier strip
Power radiator
66
2 W
approx. 880 nm
30 kHz – 6 MHz
50 mV – 3 V / approx. 5 kΩ
BNC sockets / barrier strip
50 mV
25–35 V DC via NT 1015 plug-in mains unit
or via SI 1015 modulator
0.75 A at 25 V
max. 60 mA
approx. 250 x 100 x 80
approx. 1.3 kg
Plug-in mains unit
100 – 240 V AC without switching
29 V DC
1.7 A, for powering an SI 1015 modulator
and two SZI 1015 power radiators or an
SI 1015 modulator and one SZI 1029-24
high power radiator