Battery Temperature below 0°C or above 45°C
Continuous lighting of the red LED indicator
indicates that the temperature of the battery is
not within the allowable charging temperature
range, see section "Technical Data". As soon as the allowable
charging temperature range is reached, the battery charger
automatically switches to rapid charging.
When the battery is not within the allowable temperature
range, the red battery LED lights up when inserting the bat-
tery into the battery charger.
No Charging Procedure Possible
If a different malfunction of the charging pro-
cedure is present, this will be indicated
through flashing of the red LED indicator.
The charging procedure cannot be started and the battery
cannot be charged (see section Troubleshooting).
Charging Advice
With continuous or several repetitive charging cycles without
interruption, the charger can warm up. This is not meaning-
ful and does not indicate a technical defect of the battery
charger.
A significantly reduced working period after charging indic-
ates that the battery is used and must be replaced.
Observe the notes for disposal.
Battery Cooling (Active Air Cooling)
The fan control integrated into the charger monitors the tem-
perature of the inserted battery. When the battery temperat-
ure is above 30 °C, a fan cools down the battery to the op-
timal charging temperature. The fan generates a ventilation
sound when switched on.
If the fan is not running, the battery temperature is within the
optimum charge-temperature range or the fan is defective.
Troubleshooting
Cordless leaf blower
Problem
Possible Cause
Machine fails to oper-
Battery discharged
ate
Battery too hot/cold
Machine defective
Internal wiring of garden tool defective
Garden tool function-
On/Off switch defective
sintermittently
Excessive vibrations/
Machine defective
noise
Run time per battery
Battery has not been used for long period or only
charge too low
for short terms
Battery dead or defective
Air inlet/outlet blocked
Bosch Power Tools
In this case, the charging time of the battery might be exten-
ded.
Charging Advice
With continuous or several repetitive charging cycles without
interruption, the charger can warm up. This is not meaning-
ful and does not indicate a technical defect of the battery
charger.
A significantly reduced working period after charging indic-
ates that the battery is used and must be replaced.
Observe the notes for disposal.
Operation
Caution: Switch garden tool off and remove battery
u
from machine before adjusting or cleaning.
Switching On and Off (see figure D)
To switch on, turn the On/Off switch (1) toward the rear.
The airflow speed is variable. To increase the airflow speed,
turn the On/Off switch (1) toward the rear. To reduce the
airflow speed, turn the On/Off switch (1) toward the front.
To switch off, turn the On/Off switch (1) toward the toward
the front to the stop.
Disassembling (see figure B)
Press button (2) in and remove the nozzle (5).
Working instruction (see figure E)
When operating, always hold the machine approximately
3 cm above the ground.
Do not blow hot, flammable or explosive material.
Corrective Action
Recharge battery
Allow to cool/warm
Contact Service Agent
Contact Service Agent
Contact Service Agent
Contact Service Agent
Fully charge battery; also see "battery charging"
Replace the battery
Clear the air inlet/outlet