G) Electrical Connection Heat Regenerative DH Models
Open control shroud, and identify location of Miniature Circuit Breaker (MCB).
Feed supply cable through cut outs provided in instrumentation shroud support bracket, allowing adequate cable
for connection.
Remove MCB cover and connect three phase supply and neutral to the terminals provided.
Please note a suitable cable gland must be fitted to the MCB when wiring is connected.
If a bare earth wire is used, a green/yellow insulating sleeve must be fitted.
H) Commissioning
IMPORTANT INFORMATION CONCERNING THE WARRANTY
Each dryer must undergo a detailed commissioning procedure.
This must be carried out by domnick hunter or an approved engineer from a domnick hunter authorised
distributor.
During commissioning, ensure that the dryer is installed and continuously maintained and operated in the manner
specified in this manual.
HEAT REGENERATIVE ELECTRIC CONTROLLER
27