9. Test run
F
E
D B
TEST RUN
C
COOL, HEAT
˚C
˚C
SIMPLE
TEMP.
ON/OFF
MENU
ON/OFF
FILTER
BACK
MONITOR/SET
DAY
CHECK
TEST
PAR-21MAA
CLOCK
OPERATION
CLEAR
H G
I
M
Fig. 9-2
B
E D
ERROR CODE
TEMP.
ON/OFF
C
MENU
ON/OFF
FILTER
BACK
MONITOR/SET
DAY
CHECK
PAR-21MAA
CLOCK
OPERATION
CLEAR
A
Fig. 9-3
h
ON/OFF
TOO
TOO
WARM
COOL
The OPERATION INDICATOR
lamp comes on regardless of
the remote controller display.
Fig. 9-4
A ON/OFF button
B Test run display
C Indoor temperature liquid line tem-
perature display
D ON/OFF lamp
E Power display
F Error code display
Test run remaining time display
A
G Set temperature button
H Mode selection button
I Fan speed button
M TEST button
ERROR CODE
B
E
TEST
ERROR CODE
F
OPERATION INDICATOR lamp
9.2.2. Wired remote controller (Fig. 9-2)
1 Turn on the power at least 12 hours before the test run.
2 Press the [TEST] button twice. ➡ "TEST RUN" liquid crystal display
3 Press the [Mode selection] button. ➡ Make sure that wind is blown out.
4 Press the [Mode selection] button and switch to the cooling (or heating) mode.
➡ Make sure that cold (or warm) wind is blown out.
5 Press the [Fan speed] button. ➡ Make sure that the wind speed is switched.
6 Check operation of the outdoor unit fan.
7 Release test run by pressing the [ON/OFF] button. ➡ Stop
8 Register a telephone number.
The telephone number of the repair shop, sales office, etc., to contact if an error
occurs can be registered in the remote controller. The telephone number will be
displayed when an error occurs. For registration procedures, refer to the operation
manual for the indoor unit.
9.3. Self-check
9.3.1. Wired remote controller (Fig. 9-3)
1 Turn on the power.
2 Press the [CHECK] button twice.
3 Set refrigerant address with [TEMP] button if system control is used.
4 Press the [ON/OFF] button to stop the self-check.
A CHECK button
B Refrigerant address
C TEMP. button
D IC:
Indoor unit
OC: Outdoor unit
E Check code
F Unit address
9.3.2. Wireless remote controller (Fig. 9-4)
1 Turn ON the power.
2 While pressing both the MODE SELECT button and TOO COOL button on the
remote controller at the same time, press the RESET button.
3 Release the RESET button.
4 Release the other two buttons. After three seconds, all items in the LCD are dis-
played.
5 Transmit the signal of remote controller by pressing the OPERATE/STOP (ON/
OFF) button on the remote controller.
(The above procedure allows OPERATION INDICATOR lamp to indicate the fail-
ure-mode.)
6 Transmit the signal of remote controller by pressing the OPERATE/STOP (ON/
OFF) button to stop the self-check.
13