Cage tension spring
Flat screwdriver
Cable
clamp
Connect the positive supply cable battery II (red 10 mm²) to the contacts 16, 17,
19, 20, 21, and 22 of the device (fig. 17) and the positive pole of the battery II.
It is essential to install a 40 A fuse near the positive pole of the battery II!
Connect the positive cable of the battery I (red 10 mm²) to the contacts 26 and
27 of the device (fig. 17) and to the positive pole of the battery I. It is essential
to install a 40 A fuse near the positive pole of the battery I!