Gas Pressure; Before Initial Use - Dometic Classic 1 Notice D'utilisation

Masquer les pouces Voir aussi pour Classic 1:
Table des Matières

Publicité

Classic
6.1
Specifications for the portable grill models
The portable grill is available in different models and with different connections:
• Classic 1: portable grill with three cooking rings
• Classic 2: portable grill with two cooking rings
All models are available with the following connections:
• Connection pressure 30 mbar
• Connection pressure 50 mbar
6.2

Gas pressure

The permitted gas pressure can be found on the type plate in the bottom of the case.
Models with a gas cylinder connection must be used with a pressure reducing valve.
Only use pressure reducing valves that have been specified and approved in your
country.
!
WARNING! Beware of injury
The outlet pressure of the valve must always match the connection pres-
sure (gas pressure) of the portable grill.
7

Before initial use

Proceed as follows (fig. 1, page 3):
➤ Remove the protective film from the top of the burner (1).
➤ Screw the handle (9) into the lower part of the case with both the screws M3.
➤ Attach the lock (10) to the lid of the case with the screw M4.
➤ Clean the rack and the drip tray with a standard cleaning agent.
➤ Only when connecting to gas cylinders:
– Use a suitable gas hose and a pressure reduction valve (both not included in
delivery).
– Connect the pressure reduction valve to the free end of the gas hose.
➤ Only when connecting to gas sockets: Use a suitable gas hose (not included
in delivery).
➤ Connect the gas hose to the injector (2).
EN
Before initial use
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Classic 2

Table des Matières