Installation Instructions – Epic Medium
ARM INSTALLATION
Bishop Arm (SA6001-SA6002, SA6050-SA6051,
SA6101-SA6102 & SA6150-SA6151)
See Figure 1.
1.
Secure arm mount flush with wall using 3/8" hardware
supplied by others.
2.
Remove wireway cover screws and wireway cover.
3.
Mount arm to arm mount positioning service leads in
wireway. Insert and tighten four screws to 80 in/lbs.
4.
Pull fixture leads through arm.
5.
Align locating pin and socket when raising fixture to
arm. See Figure 2.
6.
Insert and tighten 4 fixture screws with Teflon washers,
provided in polybag, to 80 in/lbs.
7 .
Connect fixture leads to service leads in wireway.
8.
Resecure wireway cover with wireway cover screws
tightened to 50 in/lbs.
Backplate Med
Bishop Wall
(4) 3/8-16 x 1-1/4
Button Head Cap
Screws
(4) 3/8" Lag Bolts
(supplied by
others)
Wireway Cover Srews (2)
Wireway Cover
Figure 1.
Aligning Pin
Aligning Socket
Figure 2a.
2
Cooper Lighting Solutions
Bishop Arm
Fixture Screws (4)
Teflon Washer (4)
Modern Top
IB516119EN
Installation instructions
Figure 2b.
These instructions do not claim to cover all details or varia-
tions in the equipment, procedure, or process described, nor
to provide directions for meeting every possible
contingency during installation, operation or maintenance.
When additional information is desired to satisfy a problem
not covered sufficiently for user's purpose, please
contact your nearest representative.
Traditional Arm (SA6003-SA6004, SA6052-SA6053,
SA6103-SA6104 & SA6152-SA6153)
See Figure 3.
1.
Secure arm mount flush with wall using 3/8" hardware
supplied by others.
2.
Remove wireway cover screw and wireway cover.
3.
Mount arm to arm mount positioning service leads in
wireway.Insert and tighten set screw to 80 in/lbs.
4.
Pull fixture leads through arm.
5.
Align locating pin and socket when raising fixture to
arm See Figure 2.
6.
Insert and tighten 4 fixture screws with Teflon washers,
provided in polybag, to 80 in/lbs.
7 .
Connect fixture leads to service leads in wireway.
8.
Resecure wireway cover with wireway cover screw
tightened to 50 in/lbs.
Classical Top
Aligning Socket
Aligning Pin

Publicité