Fix the hook-on bracket
2-2)
Use the wall-mounting bracket as a template
for positioning the heater.
Drilling points A
Drilling points B
Note : Do not use the device as a mobile unit, eg on feet or casters, except plinth model.
2-3 ) Connect the panel heater
- The appliance should have à 230-240V 50Hz power supply.
- The panel heater must be connected to the mains by a 3-
wire cable ( Brown= Phase, Blue= Neutral, Black= Pilot
wire) by means of a connection box. In humid areas such as
bathrooms and kitchens the connection box must be ins-
talled at least 25 cm above the floor.
- The installation should be fitted with a double pole break
device with a break of at least 3mm
- Earthing is prohibited.
Do not connect the pilot wire ( black ) to earth.
- The heater must be installed by a qualified electrician in ac-
cordance with the local regulations. The heater and the
pilot (black) wire must NOT be connected to earth.
- If the power cable is damaged, it must be replaced by the
manufacturer or its after-sales service Department or a
similary qualified person to avoid any risk.
- If a pilot or piloted panel heater is protected by a 30mA differential (e.g. bathroom) the pilot wire's power supply must be
protected on this differential.
Absence de
Ordres reçus
courant
Oscilloscope
Réf/Neutre
Mode obtenu
CONFORT
Lock the appliance on the hook-on bracket
2-4)
1) Description of the control unit
A Mode cursor
B Eco reduction set value adjustment knob
C Comfort temperature set value adjustment knob
V1 Heating light indicator
V2 Eco mode light
V3 Comfort mode light
Alternance ab-
Alternance ab-
sence de cou-
sence de cou-
rant (4ʼ57ʼʼ)
rant (4ʼ53ʼʼ)
phase 230V(3ʼʼ)
phase 230V(7ʼʼ)
CONFORT
CONFORT
-1°C
-2°C
II - U
SING THE PANEL HEATER
Panel heater cable
Phase=brown
Neutral=blue
Pilot wire=Black
Three possible cases
1st case: only one heater
2nd case: Slave heater
3rd case: Master heater
Demi-alternance
Alternance
négative
complète 230V
ECO
HORS GEL
A
V1
V1
7
PHASE
Electricity
grid
NEUTRAL
The pilot wire end is insulated
and not further connected
To the appliance with cassette or
programming unit.
To pilot wire of an electronically
controlled appliance
Demi-alternance
positive +115V
-115V
STOP HEATING
LOAD SHEDDING
B
C
-3,5°
5
V2
V2
V3
V3
GB