Atlantic F18 Notice D'utilisation Et D'installation page 7

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
The product you have just purchased has undergone numerous tests and inspections to guarantee the highest quality.Thank you
for your choice and your confidence in us.We hope it will give you entire satisfaction.
Some recommendations :
Please read the documentation before starting to install the panel heater.
Disconnect power before working on the panel heater.
Conserve the documentation, even after installation of the panel heater.
Equipment specification (indicated on the label of the device):
CAT C : device satisfying the requirements of the NF Electricité Performance (French electricity performance standards).
IP24 : Equipped protected from water splashes
Class II : Double insulation.
I - W
1) Where to install the panel heater
- This equipment was designed for domestic use. Please ask your distributor
before using it for any other purpose.
- The panel heater should be installed according to normal trade practice and in
compliance with legislation in the relevant country (the IEE Wiring Regulations).
- The device is to be installed so that switches and other controls cannot be
touched by a person in the bath or shower, except in the UK where IEE
Regulations 701.512.2 and 701.512.3 apply. These allow the use of IP24 rated
products and their integral controls in Zone 2 and outside zones.
- Comply with the minimum clearance distances as indicated in diagram 2 for
positioning of the panel heater.
- If your wall covering is laid on foam, a spacer the same thickness as the foam
must be placed under the panel heater's support. This ensures there is free
space behind the panel heater to make sure its control settings are not
adversely affected.
Do not install the panel heater:
- In a draught likely to affect the control settings (under a fan, etc.).
- Under a fixed mains power socket.
- In volume 1 of bathrooms.
It is strongly recomended not to install vertical products we manufacture above an altitude of 1000 metres.
If the device is installed at altitude the air discharge temperature will be increased
(by approximately 10°C per 1000 m of altitude).
It is forbiden ti install vertical product in horizontal position.
2) How to install the panel heater ?
Release the appliance's hook-on bracket
2-1)
We recommend that you place the radiant panel flat, face down.
Have a straight head screwdriver to hand.
HERE TO INSTALL THE PANEL HEATER
6

Publicité

Table des Matières
loading

Table des Matières