Télécharger Imprimer la page

Abus AZBW20000 Mode D'emploi page 28

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
Technical data
Detection area
Cover
Adjustment
Fresnel lens
Customer-specific
appearance
Outputs
Output 1 NO
Output 2 NC
Connected load
Current
Pulse counter
Temperature
compensation
Control
Programmable between 10 and 30 metres.
10–70° detection angle, 30 m × 30 m maximum cover.
180° panning + 90° tilting
Cover for reducing the area (if required).
28 zones per pyro pair that can be masked with shutters or special
tape (supplied).
Double-shielded silicon quad element absorbs 50,000 lux white light
Magnetically protected, quiet semi-conductor relay.
Volt free relay contact 24 V AC/DC at 50 mA with integrated 25R
series resistance, NO, alarm duration 10 seconds
Volt free relay contact 24 V AC/DC at 50 mA with integrated 25R
series resistance, NC, alarm duration 10 seconds
9 to 15 V DC.
8 mA (12 V nominal).
1–2
Temperature-dependent, digital adjustment.
Digital microprocessor – non-volatile memory.

Publicité