Knick VariTrans P 27000 Notice D'utilisation page 44

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Output data
Output
Offset
Load
for output current
for output voltage
Offset error
Residual ripple
General data
Adjustment range
ZERO pot
Adjustment range
SPAN pot
Gain error
Temperature
coefficient
3)
Cutoff frequency
Test voltage
Working voltage
4)
(basic insulation)
44
(also see 8. order information)
20 mA, 5 V, 10 V uni-/bipolar as well as
4 to 20 mA, 1 to 5 V and 2 to 10 V
calibrated selection
-100%, -50 %, 0 %, 50 %, 100 %
of output span of selected output range
≤12 V
(600 Ω at 20 mA)
2)
≤10 mA (1 kΩ at 10 V)
20 µA / 10 mV
< 10 mV
rms
±25 % of span
of selected output range
0.33 to 3.30 x final value of selected input range
(max. V
= 200 V)
in
< 0.08 % of meas. value
< 50 ppm/K of final value
> 10 kHz, < 10 Hz selectable
5 kV~ input against output
4 kV~ output against power supply
1 kV~for overvoltage category II and
pollution degree 2 to EN 61010-1
For applications with high working voltages, take
precautions to prevent accidental contact and make sure
that there is sufficient distance to adjacent devices or
sufficient insulation between them.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Varitrans p 27016 f1Varitrans p 27000 f1

Table des Matières