2.
Intended Use
The Series P 27000 universal isolators are used for galvanic isolation and
conversion of signals in the range from ±20 mV to ±200 V and ±0.1 mA to
±100 mA. Depending on the model, input and output signals are permanently
set or you can select calibrated ranges by means of DIP switches. The preset
measuring ranges do not have to be fine adjusted. Other transmission
ranges are infinitely adjustable within the ranges mentioned above using
potentiometers. Signal transmission is linear. By means of the broad-range
mains adapter, the units can be powered by voltages from 20 to 253 V AC/DC.
Type H1 is connected by means of pluggable screw clamp terminals,
type F1 by means of fixed screw clamp terminals.
Warning against misuse
Do not operate the device outside the conditions specified by
the manufacturer, as this might result in hazards to operators or
malfunction of the equipment.
VariSoft SW 108 adjustment aid
Our VariSoft SW 108 software tool is available for easier adjustment.
Download from the Internet at www.knick.de or ask for a CD.