Menu functions

The menus, shown on the display, are grouped in menus,
sub-menus (Settings") and part menus. The menus are
divided into two sections:
Start menu: Here you can select under which conditions
the hydraulic unit shall work.
Operations menu: Information concerning the operating
status is shown here.

Start menu

The start menu is shown each time the power to the hydraulic
unit is switched on. The menu consists of three steps:
Select fuse
The fuse rating must be set according to the fuse the
hydraulic unit is connected to.
Select 16 A, 32 A or 63 A.
Press OK to confirm the selection. Step three is then
displayed.
Select the output
The hydraulic output must be set depending on the machine
connected to the hydraulic unit. Select one of the following
options:
25 kW, 230 bar, 65 l/min (3300 psi, 17 US gpm)
15 kW, 210 bar, 45 l/min (3000 psi, 12 US gpm)
9 kW, 140 bar, 40 l/min (2000 psi, 10 US gpm)
Press OK to confirm the selection.
Husqvarna PP 455E Connect hose
assembly
Press OK when all hoses are connected.

Operations menu

The operations menu starts after step 3 in the start menu. All
information about operations and all setting options are
accessed from this menu.
The operations menu consists of eight menus:
1 a. Husqvarna PP-455, b Status
2 Water coolant ON/OFF?
3 Phase 1, Phase 2, Phase 3
4 Settings
5 Time
6 Total machine time
7 Battery status (only machines equipped with a radio)
8 Radio channel (only machines equipped with a radio)
12 –
English

SETTINGS AND ADJUSTMENTS

1.a Husqvarna PP-355, Start electric motor
Press the green button on the remote control to start the
electric motor.
1b. Status
Status is the main information that is always shown on the
display when the hydraulic unit with connected machine is
operational:
STATUS OK, signifies that the unit is operational and no
warning messages have been issued.
KV xx, where KV represents water coolant and xx ON or
OFF. What is shown depends on whether the water
coolant is switched on or off.
yyy BAR, where yyy represents the instantaneous
operating pressure.
When time is switched on: mm:ss, is also shown, i.e. the
time in minutes and seconds.
2. Water coolant ON/OFF?
Turn on and turn off the water coolant by pressing OK. The
display then shows: STATUS OK KV OFF/ON yyy BAR. Now
press arrow down to continue in the operations menu.
3. Phase 1, Phase 2, Phase 3
The instantaneous main voltage to the hydraulic unit is shown
under each phase name.
When the voltage becomes low, an error message is shown
on the display, see the section Error messages".
IMPORTANT! Long electrical cables with a small core cross
section can result in a voltage drop. The hydraulic unit can
then warn of a too low voltage.
4. Settings
Via this sub-menu a number of values can be changed to
affect the hydraulic unit's characteristics.
To access the sub-menu: State the four digit PIN-code 0012
with the help of the arrow keys and the OK button.
To save the settings; select Save" in sub-menu 3 OUT
SETTINGS".
Refer to the SETTINGS" section for complete information
about the setting options.