Cross-Section - WIKA A-10 Mode D'emploi

Masquer les pouces Voir aussi pour A-10:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3. Specifications
Designation
Circular connector M12 x 1 (4-pin)
GB
without mating connector
straight with solid laid cable
angled with solid laid cable
Cable outlet
unshielded
OEM version, unshielded
The stated ingress protection (per IEC 60529) only applies when plugged in using mating connectors that have the appropriate ingress
protection.
Short-circuit resistance
S
vs. 0V
+
Reverse polarity protection
U
vs. 0V
B
Insulation voltage
DC 500 V
3.8 Materials
Wetted parts
Stainless steel 316L
from 10 bar 316L and 13-8 PH
Non-wetted parts
Stainless steel 316L, HNBR, PA66
For sealing materials see "Process connections"
Materials for electrical connections see "Electrical connections"
14
Ingress
protection
IP 67
IP 67
IP 67
IP 67
IP 67
IP 67
WIKA operating instructions pressure transmitter model A-10
Wire
Cable Ø

cross-section

-
-
2
3 x 0.34 mm
4.4 mm
2
3 x 0.34 mm
4.4 mm
2
3 x 0.34 mm
4 mm
3 x 0.34 mm
4 mm
2
3 x 0.14 mm
2.85 mm
2
Cable
material
-
PUR
PUR
PUR
PUR
TPU

Publicité

Table des Matières
loading

Table des Matières