installation of stove
Installation
It is important that the stove is correctly installed from both an environ-
mental and safety point of view.
The stove must only be installed by a Gas Safe Registered engineer.
When installing the stove, all local rules and regulations, including those
referring to national and European standards must be complied with.
The installation must comlpy with the Building Regulations and Gas Safe-
ty (Installation and use) Regulation.
There must be no unauthorised modifications of the stove.
Before installation begins, it should be confirmed that the information
on the data plate regarding gas type and pressure is in accordance with
the local gas supply conditions under which the stove is to be installed.
You should ensure that the gas supply can supply the required quantity
of gas and pressure as described on the data plate. It is advisable to wear
gloves when installing and servicing the stove.

Gas connection

The inlet supply pipe has an external diameter of Ø8mm. An isolation
tap must be fitted.

Ventilation

This stove has a sealed combustion chamber and is intended for a bal-
anced draught. There is therefore no need for an extra air supply.
It is recommended that sufficient fresh air is supplied to the room to
maintain a comfortable environment.
This stove may be installed in a completely airtight building or a building
with mechanical ventilation.

Gas installation

Once it has been decided where the stove will be positioned, a gas in-
stallation should be established in the vicinity of the stove so that the gas
supply and stove can be connected.
As this stove has a sealed combustion chamber and a built-in plinth,
there is no need for a floor slab.
The installation must comply with the Building Regulations, Gas Safe-
ty (Installation & USe) Regulations, BS 5871, BS 5440-1, BS 6891 and
where relevant all LPG Codes of Practice. LPG stoves must not be fitted
in a basement.