Horizontal Wall Terminal type C11

Dimension of outflow pipe:
Viva L
Outlet terminal
Maximum length of outflow pipe to external wall (H)
= 4 X Vertical outlet pipe length (V) -1. for Ø130 / Ø200 pipe.
= 2 X Vertical outlet pipe length (V) .
Maximum permissible length (H) = 15M.
Minimum vertical height of outlet pipe for Viva L = 0.5m
vertical length of out-
let pipe
(V) in metres
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
5.5
6.5
7
7.5 <
Flue restrictor to Ø100/Ø150
Vertical height < 1m
Vertical height 1-2m
Vertical height > 2m
RAIS/
Ø100 / Ø150 Outlet connection piece on the stove
Ø100 / Ø150 Can be used for the entire chimney, or,
Ø130 / Ø200 Adapter can be used so that you can use
Ø130 / Ø200 after the adapter.
Ø130 / Ø200
Art. no. USDHC 130
Ø100 / Ø150
Art. no. USDHC 100
for Ø100/Ø150 pipe.
Maximum length of
Horizontal outlet pipe
(H) in metres Ø130/
Ø200
1
3
5
7
9
11
13
15
15
15
15
15
15
15
No flue restrictor
Ø62mm flue restrictor
Ø76mm flue restrictor
attika
- User manual for VIVA L Gas
Maximum length of
Horizontal outlet pipe
(H) in metres Ø100/
Ø150
1
2
3
4
5
6
7
8
9
10
11
13
14
15
28