Gallagher MBS1800i Notice D'installation page 19

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Gallagher 3E4346 MBS1800i MBS2800i Energizer User Manual
Fence Zone 1 - 6
View the Fence Zone performances by pressing the naviga on bu ons (< or >) un l
the zone indica on arrow is highligh ng the desired fence zone (1 - 6). The fence
zones voltage, current and alarm informa on is displayed in the same way as the
Energizer output informa on. See Energizer Output and Alarms sec on (p.14).
To adjust or turn off the fence zone alarms, see Adjus ng/Turning Off Alarms sec on
(p.15).
Low Ba ery
When viewing a zone, if the ba ery icon is displayed, then the zone device needs a
ba ery replacement.
Adjus ng the energizer output voltage
a)
Press the setup bu on (
bu ons ( < or >) to highlight the quickscan bargraph display (it will start
fl ashing).
b)
Press (+ or -) to adjust the output voltage up or down. The output voltage can
be adjusted from 4.5KV to 8KV. The factory default se ng is 8KV.
c)
To exit the setup mode wait 10 seconds or press the setup bu on (
Controller showing zone 2 with a low ba ery
) to enter setup mode and use the naviga on
Controller showing the output voltage being adjusted
).
17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mbs2800i

Table des Matières