Suppression Des Pannes - RM SPI-704 E Notice D'installation Et D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SUPPRESSION DES PANNES

Malfunction
The hotplate does
not heat up
The bulb is not lit
Insufficient heat
output
No response to the
setting regulator
being turned
The heating
switches off and on
within several
minutes. The
ventilator is running.
The heating
switches off and on
within several
minutes. The
ventilator is not
running.
The heating
switches off and on
within several
minutes. (after an
extended period of
operation without
interruption).
Small metal items
(e.g. spoons, knives)
are heating in the
cooking zone
50
Possible cause
No power supply
The power regulator is
in the "off" position
The main switch is OFF
The pan is too small
(bottom diameter less
than 12 cm)
The pan is not in the
middle of the heating
zone (the pan could not
be recognised)
Unsuitable pan
The induction cooker is
broken
The pan used is not
ideal
The ambient
temperature is too high
(the cooling system is
not capable of keeping
the hotplates at
operating temperature
*2)
One phase is missing
The induction cooker is
broken
The regulator is broken
The cooling system is
blocked/malfunctioning
Ventilator dirty.
Ventilator malfunction
or ventilator control
malfunction
The spiral is overheated.
The cooking zone is too
hot.
Empty container
Overheated oil in a pan
Incorrectly configured
cookware recognition
Precautions by users or servicing personnel
Check whether the appliance is connected to
the mains (the plug is in the socket) and
whether the main switch is on.
Turn the power regulator to the "on" position
Switch the main switch on
Use a suitable pan
Move the pan to the centre of the heating zone
Choose a pan suitable for induction* 1
Contact you supplier to request servicing.
Remove the plug from the socket.
Choose a pan suitable for induction. Compare
with the results of "your" pan.
Ensure that no hot air is being drawn into the
appliance. Reduce the ambient temperature.
The temperature must not exceed 40
o
F.
Test the circuit breakers and fuses.
Contact your supplier to request repair services.
Remove the plug from the socket.
Ensure that the air intake and off take vents are
not blocked.
Clean the ventilator.
Contact our supplier to request repair services.
Remove the plug from the socket.
Switch the cooker off, remove the cookware and
wait until the cooking zone cools.
Test the control panel (only the supplier's
servicing personnel).
o
C / 115

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Spi-704 esSpi-704 e wokSpi-704 es wokSpi-708 eSpi-708 esSpi-740 e ... Afficher tout

Table des Matières