Technical Data - Wenglor SR4E4D01S Notice D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4. Technical Data

Electrical Data
Temperature Range
Storage Temperature
Supply Voltage
Input Circuit
Response Time
Drop-out Time
Air clearances and creepage distances (EN 60664-1) 4 kV / 2 (basic insulation)
Power consumption
Frequency range
Max. fuse rating of the operating voltage
Utilisation category
Safety Output
Safety Output
Safety Outputs Stop 0
Safety Output Switching Current (250 V)
Protection of the safety contacts
Auxiliary Output
Auxiliary Output
Number of Auxiliary Outputs
Auxiliary Output Switching Current (24 V DC)
Fuse Protection of Auxiliary Output
Mechanical Data
Material
Material of the contacts
Mounting
Service Life
Connection
Conducted cross-section
Connecting Cable
Tightening torque for the terminals
Resistance to shock
Resistance to vibrations
Protection Class
Weight
Safety-technical data
Safety Category (EN ISO 13849-1), Stop 0
Diagnostic Coverage (EN ISO 13849-1)
Common Cause Failure CCF
Performance Level (EN ISO 13849-1), Stop 0
–25...60 °C
–40...85 °C
20,4...28,8 V DC
20,4...26,4 V AC
1-, 2-channel
typ. 30 ms / max. 45 ms
typ. 25 ms / max. 35 ms
< 1 VA
50 Hz / 60 Hz
F1: T 1,0 A / 250 V
AC-15: 230 V AC / 6 A
DC-13: 24 V DC / 6 A
NO
4
6 A
external (lk = 1000 A) according to EN 60947-5-1
8 A fast-acting, 6 A slow-acting
NC
2
2 A
external (lk = 1000 A) according to EN 60947-5-1
2.5 A fast-acting, 2 A slow-acting
Plastic, glass-fibre reinforced
AgSnO, self-cleaning, positive drive
quick fastening for standard rail according
to DIN EN 60715
10 million switching cycles
pluggable screwed connection
0,25...2,5 mm²
rigid or flexible
0,6 Nm
10 g / 11 ms
10 ... 55 Hz, amplitude 0.35 mm
Enclosure: IP40, Terminals: IP20, Clearance: IP54
215 g
up to 4
99 %
> 65 points
up to PL e
15

Publicité