safety precautions and usage statements
OUTPUT:
DC 29V 1.8A
WATTS:
52.2W
Product Ratings:
The lift motors are not designed to operate continuously for more
than two [2] minutes in an eighteen [18] minute time period or
approximately 10% duty cycle. Attempting to circumvent or exceed
this rating will shorten the life expectancy of the product and may
void the warranty.
Weight Limits:
The recommended weight limits on the EASE
Long / Full / Queen / King / Cal King / Cal King Split : 650 pounds
Maximum weight the bed can support per person is 250 pounds
with the weight evenly distributed across the head and foot
sections. This product is not designed to support or lift this amount
of weight in the head or foot sections alone. NOTE: Exceeding the
recommended weight restrictions could damage your EASE
void your warranty. For best performance, you should enter and exit
®
the EASE
while it is in the flat or fully lowered position.
®
EASE
fits easily inside bed frames, furniture beds and platform
beds that are certified to hold a minimum of 850 pounds. If
using this adjustable base without the legs and placing directly
on a bed frame or platform bed, cross-bed supports (slats) are
strongly recommended to ensure EASE
operation.
Exceeding this weight restriction could damage the bed
and/or cause injury and will void the warranty.
Acoustics:
In normal base operation the wheels, which allow the bed to
maintain its distance from the wall, will make contact with the
steel platform supports of the base creating a contact noise. When
entering, exiting or shifting weight on the base, this contact noise
may be audible as the wheels make contact. This is normal.
Fabric Care:
To prolong the life of your fabric, protect from direct sunlight
whenever possible. For spot cleaning, wipe area with a light
damp sponge or vacuum with a soft brush attachment to remove
particles. Keep at a minimum of 30cm (12 inches) away from direct
2
®
are: Twin / Twin
®
and
®
maintains stability during
heat sources.
For deeper cleaning, blot liquid spills with a clean dry cloth.
Wipe with a clean cloth dampened with warm water. Do not wet
excessively. A soft bristle brush may be used to remove ingrained
soil. Avoid scratching by gentle brushing. Wipe with a clean cloth
dampened with warm water to remove residues after brushing. Dry
in shade away from direct heat.
If persistent marks remain visible after cleaning, seek professional
advice.
SAVE THESE INSTRUCTIONS.
FCC Compliance:
NOTE: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of
the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for
help.
CAN ICES-3 (B)/NMB-3(B)