Completing The Installation - Airxcel 47000 Série Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

A.
Make sure the non-allergenic filters are properly
positioned in the ceiling grille.
B.
Install the ceiling grille by positioning on the bottom
of the shroud and engaging the two 1/4 turn fasteners.
C.
Turn the selector switch to OFF position.
D.
Turn ON the power supply to the roof top heat pump.
E.
Insure that a condensate hose is installed if the
optional condensate pump is provided. The
VIII. COMPLETING THE INSTALLATION
FIGURE 9
attachment point is in the return air (See Figure 9). A
1/2" barbed fitting is provided, however, removal of
the hose "pigtail" will allow use of a 1/4" I.D. hose.
F.
System Checkout – Airxcel, Inc. manufactures a wide
range of roof top heat pumps which incorporate
different product operation features. To properly
evaluate the performance of a newly installed heat
pump, it is necessary to review the specific unit
operation characteristics (features) described in
product operation and maintenance instructions
(Customer Envelope Package).