to the green pigtail wire found in the field wiring
box using the 3 provided wire nuts. IMPORTANT –
connect the black supply to the black pigtail and the
white supply to the white pigtail. Using a U.L.
approved electrical tape, secure the wire nuts to
wires in a workmanlike manner (See Figure 8).
Place the metal control box shield over the
thermostat, switch and field wiring boxes. Make
certain that all wires are pushed into the control
boxes or laying in the wireway between the
thermostat and switch boxes and will not be
pinched by the control box shield. Control box
shield is properly installed when the two holes in
shield are aligned with the two screw holes in the
ceiling assembly chute (See Figure 7).
Raise the ceiling assembly and secure to the
mounting frame with 4 provided shoulder
FIGURE 5
screw/spring assemblies. The front two screws
should pass through the clearance holes in the metal
control box shield (See Figure 9).
The ceiling assembly shroud is curved to contour to a
crowned ceiling. If installation is to a flat ceiling
and gaps are present on the sides of the shroud,
insert the four optional 3/4 inch screws (provided)
through the mounting posts and secure them to the
mounting frame above (See Figure 7, 8 & 9 for
screw locations).
Pull the fabric duct material through ceiling
assembly discharge opening. Peel the release liner
from the adhesive strip around the discharge opening.
Press the fabric duct material firmly in place around
opening. Cut off excess fabric on inside of ceiling
assembly chute with a box knife taking care not to
tear the fabric beyond the adhesive strip.
FIGURE 6
FIGURE 7
FIGURE 8
8