SYMPTOM
Low use time per
battery charge
Blinking orange
light on charge
state indicator
Blower Model BL300
Troubleshooting
POSSIBLE CAUSE
Excessive use of turbo
mode
Battery pack not fully
charged
Battery pack is at the
end of its life
Charger short circuit,
charger over current,
over voltage limit, open
circuit on battery pack, or
charge/pre-charge time
out error
RECOMMENDED ACTIONS
Use turbo only when needed to move dense, heavy or
wet material
Recharge See "Battery Pack and Charger"
All batteries have a finite life If the battery pack
is more than two years old or has been recharged
frequently, it may be time to replace it Replace only
with the battery pack specified for this blower
1 Make sure the charger cord is connected to both
the charger and the electrical outlet
2 Make sure the charger is receiving the correct
voltage
3 Try charging another battery pack designed for this
charger
If this does not correct the problem, have the function
checked at an approved service location