DEDPV-705 Fan/Switch Installation Instructions
Indicator Panel Installation
Step 1. Selecting Panel Location
The DEDPV-705 indicator panel mounts near the dryer in a location that will be visible to the
operator of the dryer. The indicator panel is supplied with 50 feet of cable. Ensure that the
indicator panel and (DEDPV) are located to allow their connection with this cable.
BLACK
RED
Step 2. Wiring and Mounting Panel
The indicator panel is a low voltage device that is not required to be installed in an electrical
junction box. If provided with clearance for the cable and terminal block it can be mounted to a
wall using appropriate fasteners. Once mounted to the wall attach label furnished in the kit to the
4" x 4" indicator cover plate.
If installer chooses to mount indicator panel in a single gang junction box (by others), it should not
be installed in a box that contains line voltage wiring or devices.
On the end of the 50 foot cable with stripped wires connect red wire to the positive (+) position
of the terminal block on the indicator panel. Connect black wire to the negative (-) position of the
terminal block on the indicator panel.

Fan Installation

Step 1. Selecting Fan Location
Mount Bracket
The indicator panel is supplied with 50 feet of cable. Ensure that the indicator panel and boost fan
are located to allow their connection with this cable. Fan must be mounted a minimum of 5 linear
feet from the dryer outlet. In order to perform recommended maintenance, fan location shall allow
sufficient access for service. Refer to dimensional drawings shown on the next page. When the
DEDPV is installed in an attic, crawl space or any other cold areas, it is strongly recommended to
insulate the fan to prevent condensation risks.
NOTE: Steps 2 & 3 may be reversed.
Step 2. Mount Bracket
Using the 3/4" long wood screws provided, attach the mounting bracket to a support beam at the
selected location. Fan mounting can be done at any angle (see illustrations on the top of the next
Mount Fan
page), however, vertical mounting is recommended to reduce condensation buildup in the fan. If a
horizontal installation is necessary and condensation buildup may pose a problem, a 1/4" hole
drilled in the bottom of the housing (along with an NPT insert (by others) and drain tubing) may be
installed to allow condensation to drain.
Step 3. Mount Fan
For proper operation, the control box (located on the fan) needs to be positioned properly.
Illustrations on the top of the next page show the correct control box position for fans that are
mounted horizontally, vertically and at an angle. The control box should also be positioned to
provide access to the indicator panel wiring and the tubing connections. Attach fan to the
mounting bracket with the 1/2" long self tapping screws provided. Care should be taken not to
strip the housing. Although screw pilot holes are not required, 3/32" (or smaller) pilot holes are
Mounting Bracket and
recommended.
Screw Locations
Step 4. Duct Installation
Leave adjoining dryer duct a minimum of 10-1/8" away from fan inlet and outlet. Install the 10"
long cleanout duct using the FC4 duct clamps. See dimensional data on the next page.
Step 5. Connect Indicator Panel Cable
Connect the end of the 50 foot cable that has a two position connector to the receptacle located
on the dryer booster fan control box.