Racer INVERTER 7 Notice D'installation Et D'utilisation page 82

Pompe à chaleur de piscine
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Malfunction
IPM module temperature
too high protection
PFC module protection
DC fan motor failure
PFC module thermal
circuit is abnormal
PFC module high
temperature protection
Input power failure
Error
code
1. Output
module thermal circuit
EE15
2. Motor is abnormal or damaged
3. Fan blade is broken
1. Output
module
2. Motor is abnormal or damaged
EE16
3. Fan blade is broken
4. Input voltage leap, input power
is abnormal
1. DC motor is damaged
2. Main board is damaged
EE17
3. The fan blade is stuck
EE18
The driver board is damaged
1. PFC module thermal circuit
output abnormal
2. Motor is abnormal or damaged
EE19
3. Fan blade is broken
4. The screw in the driver board is
not tight
The supply voltage fluctuates too
EE20
much
Reason
exception
of
IPM
exception
of
PFC
- 79 -
Solution
1. Change a driver board
2. Check if the fan motor speed
is too low
or fan motor
damaged, change another one
3. Change another fan blade
1. Change a driver board
2. Check if the motor speed is
too low or fan motor damaged,
change another one
3. Change another fan blade
4. Check the input voltage
1. Detect DC motor, replace
with a new one
2. Change a new main board
3. Find out the barrier and work
it out
1. Change a new driver board
2. Check if the fan motor speed
is
too
low
or
fan
damaged, change another one
1. Change a new driver board
2. Check if the motor speed is
too low or fan motor damaged,
change another one
3. Change another fan blade
4. Check if the screw is loose
Check whether the voltage is
stable
motor

Hide quick links:

Publicité

Chapitres

Table des Matières
loading

Produits Connexes pour Racer INVERTER 7

Table des Matières