Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

easy2wire ADB
| ENGLISH
INTRODUCTION
Easy2Wire DOOR INTERCOM SYSTEM
Thank you for purchasing the Easy2Wire intercom system. You have
acquired a high-quality system with a stainless steel cover. The stainless
steel covers are made carefully by hand and therefore have individual
characteristics that should be considered a mark of quality.
Notes on the care of stainless steel
Never clean the stainless steel surfaces with commercial cleaning pro-
ducts as these are too aggressive. Please only clean them with stainless
steel cleaner or care spray. If this is not available use only clear water.
Failure to observe this care tip can lead to discoloration or in the worst
case to rust damage.
PACKAGE CONTENTS
ADB-1140
1x One-family outdoor station
1x Indoor station
GB
1x Mounting materials
1x Operating and assembly instructions
ADB-1240
1x Two-family outdoor station
2x Indoor station
1x Mounting materials
1x Operating and assembly instructions
ADB-40
1x Indoor station
1x Mounting materials
1x Operating and assembly instructions
LEGEND

Outdoor station

A.1 Loudspeaker openings
A.2 Ringer button
A.3 Illuminated field
A.4 Microphone
A.5 Casing screws
A.6 Terminal cover
A.7 Screws for terminal cover
A.8 Front cover screws
A.9 Brightness sensor
A.10 Volume potentiometer
A.11 DIP switch for opening time of door opener
A.12 Contact terminal for door opener
A.13 Contact terminal for power supply
A.14 Contact terminal for signal line
Indoor station
B.1 Mute button
B.2 Door opener button
B.3 Microphone
B.4 Talk button
B.5 Internal button
B.6 Melody
B.7 Volume +
B.8 Volume -
B.9 Potentiometer for ringer volume
B.10 Back of casing
B.11 Terminal for supply voltage
B.12 Terminal for BUS input
B.13 Terminal for BUS output
B.14 DIP switch for encoding
B.15 Connection for VTX-Bell
OUTDOOR STATION
INSTALLATION
The following wires are required:
2 wires from the outdoor station to the indoor station(s) and 2 wires
from the outdoor station to the door opener. The lines can either be
laid radially or station-to-station. There are two terminals in the indoor
station for the BUS line (input and output) for a station-to-station
connection, for radial wiring the BUS line is only connected to the input.
The supply voltage is either connected to one indoor station or to the
outdoor station. There should not be a double feed.
Connection of a door opener
The door opener is connected directly to the outdoor station with two
lines. No additional power supply is necessary to control the door
opener. The door opener must be designed for 12-volt direct voltage
and may not require more than 1 A current. Some door openers require
correct poling.
10 10

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Easy2wire adb-1240Easy2wire adb-40

Table des Matières