Cut off the power from the appliance (remove the fuses).
To reach the parts more easily, remove the front panel.
Before removing the panel, remove the temperature
adjustment knob, the handle of load water tap and the
control handwheel of the cooking tilting pan.
Replacement of heating elements
- Disconnect the power cables to the heating element/s.
- With the tilting pan models to facilitate the replacement,
rotate the tank to the maximum opening.
- Remove the sheet insulation protection by unscrewing
the tank fixing screws.
- Remove the heating element protection panel.
- Remove the heating element supporting plate from the
damaged heating element.
- Assembly the new heating element by following the
sequence in reverse.
EN
Replacing the lights
- Disconnect the power supply cables.
WARRANTY CERTIFICATE
COMPANY NAME:
ADDRESS:
____________________________________________________________________________________________________
POSTAL CODE:
PROVINCE:
_______________
ATTENTION!
The manufacturer declines all responsibility for any inaccuracies in this handbook due to typing or printing errors.
The manufacturer reserves the right to make any changes that may be required without altering the basic features of the
product.
The manufacturer declines all responsibility in the event that the instructions given in this handbook are not fully
observed.
The manufacturer declines all responsibility for any direct or indirect damaged caused by incorrect installation, tampering,
poor maintenance and negligent use.
PART REPLACEMENT
(SPARE PARTS)
____________________________________________________________________________________________
TOWN:
___________
___________________________________________________________________________
INSTALLATION DATE:
MODEL.
PART NUMBER:
MOD.
Qn
V
- Remove the lamp.
- Assemble the new lamp by following the sequence in
reverse.
Replacing the operating thermostat or the safety
thermostat
- After removing the front panel, disconnect the power
supply cables.
- Remove the bulb, located at the tank bottom, from the
front side.
- Remove the thermostat by unscrewing the support
fixing screws.
- Assemble the new thermostat by following the
sequence in reverse.
Replacing the switch
- After removing the front panel, disconnect the power
supply cables.
- Replace the switch, unscrewing the support fixing
screws; the operating coaxial thermostat should have
been removed.
- Assemble the new switch by following the sequence in
reverse.