INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOME OWNER.
CHECK THE BOXES TO INDICATE THAT THE CORRESPONDING STEPS HAVE BEEN COMPLETED.
Natural Gas to Propane Includes
BL36-2 / CBL36-1
Kit W175-0636
1
Regulator
1
#56 Burner Orifice
1
#35 Pilot Orifice (LP)
1
Conversion Data Label
(C)BL42
Kit W175-0740
1
Regulator
1
#55 Burner Orifice
1
#35 Pilot Orifice (LP)
1
Conversion Data Label
(C)BL56
Kit W175-0738
1
Regulator
1
#53 Burner Orifice
1
#35 Pilot Orifice (LP)
1
Conversion Data Label
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions
and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is
not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal
injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is
not proper and complete until the operation of the converted appliance is checked as specified in the owner instructions
supplied with the kit.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically
approved with this appliance may result in property damage or personal injury.
CAUTION: Before proceeding with conversion shut off gas supply and disconnect electrical power.
1.
Lift safety barrier up and out from the appliance.
2. Remove the door hanger trim, glass door and the media.
3. Remove the decorative panels and support brackets where
applicable.
4. Remove the burner, end covers, and media tray. Screw
quantities vary per model (FIG. 1).
5. Using a 1/2" deep socket, remove the main burner orifice.
Use a 1/2" wrench to ensure that the manifold tubing does
not twist or kink. Replace with the orifice supplied.
6. To convert the pilot, remove the clip from the side of the
pilot with pliers. Pull the pilot hood off. Using a 5/32" hex
head Allen key, remove the pilot orifice. Replace the pilot
orifice with the one supplied. Align the pilot hood back to its
original position and place the clip back on the pilot. (FIG. 2)
7.
Before replacing the burner assembly, adjust the air shutter
(See "VENTURI ADJUSTMENT" chart).
8. Replace and re-secure the burner assembly ensuring that
the venturi fits over the burner orifice.
9. Reinstall the media tray and end burner covers.
10. To convert the main valve, follow the instructions that are
supplied with the regulator assembly kit. IMPORTANT: Use
the screws provided with regulator.
11. The conversion data label must be filled out and attached
adjacent to the valve.
12. Refer to the lighting instructions in your installation manual.
Turn on the electrical supply to the appliance. Turn on gas supply. Light the pilot and burner while continuing to
check for gas leaks by using a calibrated electronic sniffer, leak fluid, or brushing on a soap and water solution.
Do not use open flame.
13. Ensure the gas lines have been purged. Purge all gas lines with the glass door off. Ensure that a continuous flow
is at the burner before replacing the glass door and safety barrier.
14. Once all systems have been checked, reinstall decorative panels and media.
15. Reinstall the door, door hanger trim and safety barrier.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8, Canada
1 (866) 820-8686 · www.napoleon.com
FUEL CONVERSION KIT FOR MODELS
BL36-2 / CBL36-1 / (C)BL42 / BL46-1 / CBL46 / (C)BL56 / (C)BL76
These kits are for use at altitudes of 0 to 4500 feet.
BL46-1 / CBL46
Kit W175-0635
1
Regulator
1
#53 Burner Orifice
1
#35 Pilot Orifice (LP)
1
Conversion Data Label
(C)BL76
Kit W175-10010496
1
Regulator
1
#52 Burner Orifice
1
#35 Pilot Orifice (LP)
1
Conversion Data Label
Propane to Natural Gas Includes
BL36-2 /CBL36-1
Kit W175-0637
1
Regulator
1
#48 Burner Orifice
1
#62 Pilot Orifice (NG)
1
Conversion Data Label
(C)BL42
Kit W175-0741
1
Regulator
1
#45 Burner Orifice
1
#62 Pilot Orifice (NG)
1
Conversion Data Label
(C)BL56
Kit W175-0739
1
Regulator
1
#41 Burner Orifice
1
#62 Pilot Orifice (NG)
1
Conversion Data Label
BL46-1 / CBL46
Kit W175-0634
1
Regulator
1
#43 Burner Orifice
1
#62 Pilot Orifice (NG)
1
Conversion Data Label
(C)BL76
Kit W175-10010495
1
Regulator
1
#37 Burner Orifice
1
#62 Pilot Orifice (NG)
1
Conversion Data Label
BL46-1 Illustrated
HOOD
PILOT ORIFICE
CLIP
W415-1722 | E-0
FIG .1
FIG.2
loading

Sommaire des Matières pour Napoleon Ascent Linear 36

  • Page 1 14. Once all systems have been checked, reinstall decorative panels and media. 15. Reinstall the door, door hanger trim and safety barrier. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8, Canada W415-1722 | E-0 1 (866) 820-8686 · www.napoleon.com...
  • Page 2 UPPER 3/8” (9.5mm) TO 1/2” Low flame (valley) Tall flame (peak) (12.7mm) OF FLAME SENSOR ÉLECTRODE VEILLEUSE Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8, Canada W415-1722 | E-0 3/8” - 1/2” 1 (866) 820-8686 · www.napoleon.com (9,5mm - 12,7mm) LA SONDE...
  • Page 3 14. Une fois tous les systèmes vérifiés, réinstallez les panneaux décoratifs et le média. 15. Réinstallez la porte, la garniture de suspension de porte et la barrière de sécurité. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8, Canada W415-1722 | E-0...
  • Page 4 Low flame (valley) Tall flame (peak) ENVELOPPER LA PARTIE SUPÉRIEURE DE LA SONDE DE FLAMME DE 3/8” (9,5mm) À 1/2” (12,7mm) Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8, Canada W415-1722 | E-0 1 (866) 820-8686 · www.napoleon.com...

Ce manuel est également adapté pour:

Ascent linear 46Ascent linear 56Bl36-2Cbl36-1Bl42Cbl42 ... Afficher tout