General Comments; Safety Guidelines; Intended Use - Honeywell KaltecSoft Notice D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29
1
Introduction

1.1 General comments

Please read this manual carefully and familiarise yourself with
the operating instructions before using the equipment.
Local standards as well as technical specifications must be
observed.
The operating instructions must be read in conjunction with
any national regulations concerning accident prevention and
environmental protection.
Prior to operating the device, read the operating instructions
completely and thoroughly.
Please keep this manual close to hand for quick reference.
The device shall only be used for its intended purpose, in line
with the operating instructions and only in the environment to
which intended.
Note:
Never exceed the defined maintenance and service
intervals.

1.2 Safety Guidelines

CAUTION!
Danger caused by electric current or voltage!
Always consult a qualified electrician when working on places
denoted by this symbol.
The complete power supply unit must be replaced in the
event of damage to the mains cable.
CAUTION!
Do not use any aggressive cleaning agents!
If a power failure occurs when regeneration waste water and
overflow are being drained into a sump, flooding may occur.
Always fit an overflow drain.
CAUTION!
Use only trained or instructed staff. Stipulate clear
staff responsibilities for operation, set-up,
maintenance and repair work.
CAUTION!
NEVER operate the device with the housing covers
removed.
If needed, use protective clothing.
Additional information for the operator.

1.3 Intended use

The Honeywell softener is designed for softening or partially
softening domestic water (in accordance with the relevant
regulations e.g. for drinking water).
All other use is strictly forbidden and is your own
responsibility.
Honeywell GmbH
GB
1.4 Technical Data
1.4.1Softener data
Connection/Sizes
OS.-No.:
Conn. size ext. thread BSP
/ Nominal diameter:
Dwelling units:
KS30E-30, KS30I-30
KS30E-60, KS30I-60
KS30I-80
Electrical connection:
Pressure values
Max. flow rate:
Operating pressure range: 1 - 8 bar
Operating temperatures
Drinking water
temperature range:
Ambient temperature
range:
Specifications
Nominal flow rate
@∆p=1.0bar acc. to
EN 14743:
KS30E-30, KS30I-30
KS30E-60, KS30I-60
KS30I-80
Quantity of ion-exchange
resin:
KS30E-30, KS30I-30
KS30E-60, KS30I-60
KS30I-80
Nominal capacity
(EN 14743) :
KS30E-30, KS30I-30
KS30E-60, KS30I-60
KS30I-80
Capacity salt reservoir:
KS30E-30, KS30I-30
KS30E-60, KS30I-60
KS30I-80
Max. salt consumption per
regeneration:
KS30E-30, KS30I-30
KS30E-60, KS30I-60
KS30I-80
2
KS30E-30, KS30E-60,
KS30I-30, KS30I-60, KS30I-80
3
/
" (DN20)
4
1 - 3
3 - 8
6 - 20
230 V / 50 Hz
3
3 m
/h
5 - 30 °C
5 - 40 °C
3
1.44 m
/h
3
1.68 m
/h
3
1.68 m
/h
10 l
20 l
25 l
³
30 m
x °dH/ 54 °fH/ 540 ppm
³
60 m
x °dH/107 °fH/1070 ppm
³
85 m
x °dH/151 °fH/1510 ppm
12 kg
25 kg
25 kg
1.5 kg
2.5 kg
3 kg
MU0H-1420 GE23 R0618

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ks30eKs30i

Table des Matières