Limit:
Approx. 40 mA
Residual ripple:
< 20 mV ss
Time constant:
Approx. 3 ms
1
Response time
acc. to IEC 770:
Approx. 15 ms
DC voltage signal U
: 0...10 V
A
Voltage drop U
:
V
< 2.6 V
for the standard (non-Ex) version
< 4.5 V
for Ex versions
(input signals "intrinsically safe")
< 6.1 V
for Ex versions
(output signals "intrinsically safe")
500 Ω
Internal resistance:
Limit:
< 26 V
for the standard (non-Ex) version
< 16 V
for Ex versions
(input signals "intrinsically safe")
< 16 V
for Ex versions
(output signals "intrinsically safe")
Residual ripple:
< 20 mV ss
Time constant:
Approx. 3 ms
Response time
1
acc. to IEC 770:
Approx. 15 ms
Accuracy data
< ± 0.1%
Error limits:
(Reference value 20 mA including
linearity error)
< ± 0.2%
(Reference value 10 V including
linearity error)
Ambient conditions
Operating temperature: – 25 to + 55 °C,
– 20 to + 55 °C
(Ex versions: input or output signals
"intrinsically safe")
– 40 to + 70 °C
Storage temperature:
Annual mean
≤ 75% standard climatic rating
relative humidity:
≤ 95% improved climatic rating
Seismic test:
5 g, < 200 Hz,
2 h in each of 3 directions
Shock:
50 g,
10 shocks in each of 3 directions

6. Exchanging frontplates

Apply gentle pressure to the transparent cover as shown in
Fig. 3 (left) until it pops out on the opposite side. The label in
the cover can be replaced and used for notes.
After replacing the label in the transparent cover, the trans-
parent cover can be snapped into the front of the device
again. This is done by inserting it behind the edge at the
bottom and pressing it gently down and to the rear with the
finger until it snaps into place (right side of Fig. 3).
2
3
ON
ON
(
Fig. 3. Left: Removing the transparent cover
Right: Inserting the transparent cover.
7. Mounting
The SINEAX TI 807 can be mounted either on a top-hat rail or
directly onto a wall or mounting plate.
Make sure that the ambient temperature stays
within the permissible limits:
– 25 and + 55 °C for standard instruments
– 20 and + 55 °C for instruments in Ex version!
7.1 Top-hat rail mounting
Simply clip the device onto the top-hat rail (EN 50 022) (see
Fig. 4).

7.2 Wall mounting

While pressing the latch (4) in the base of the device (Fig. 5,
left) pull out the transmitter securing brackets (1). To return
the brackets to their original positions, the latch (5) in the
base of the device has to be depressed before applying
pressure to the securing brackets (1) (see Fig. 5, right).
(1)
(1)
(2)
(3)
(2)
(4)
(5)
(1)
(1)
1
This is the time which transpires before the output signal reaches
the error limit of 1% for a step change of the input signal from
0
90%.
= 250 Ω.
2
With current signal and R
A
3
With voltage signal
Fig. 4. Mounting on
top-hat rail 35 × 15
or 35 × 7.5 mm.
Fig. 5. Rear of device.
(1) Screw hole brackets
(2) Top-hat rail clip
(3) Rubber buffers
(4) Latch for pulling
the screw hole
brackets out
(5) Latch for pushing
the screw hole
brackets in
13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sineax ti 807-1

Table des Matières