Read First And Then; Scope Of Supply; Brief Description; Specification And Ordering Information - Camille Bauer SINEAX TI 807 Mode D'emploi

Séparateur galvanique passif
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating Instructions
Passive DC signal isolator SINEAX TI 807-1
Contents
1. Read first and then... ................................................ 12
2. Scope of supply ........................................................ 12
3. Brief description ........................................................ 12
5. Technical data ........................................................... 12
6. Exchanging frontplates ............................................. 13
7. Mounting ................................................................... 13
8. Electrical connections ............................................... 14
9. Commissioning and maintenance ............................ 15
10. Releasing the signal isolator ..................................... 15
11. Dimensional drawings ............................................... 15

1. Read first and then ...

The proper and safe operation of the device
assumes that the Operating Instructions are
read carefully and the safety warnings given
in the Sections
7. Mounting
8. Electrical connections
are observed.
The device should only be handled by
appropriately trained personnel who are
familiar with it and authorised to work in
electrical installations.

2. Scope of supply

Signal isolator (Fig. 1)
1 Operating Instructions (Fig. 2), in three languages:
English, French and German
1 Ex approval (Fig. 2), only for Ex version devices
Camille Bauer AG
Fig. 1
Fig. 2

3. Brief description

The signal isolator SINEAX TI 807 serves to electrically
insulate two or three analogue DC signals in the range
0...20 mA which depending on version is then converted to
a current or voltage signal (0...20 mA or 0...10 V). It does not
require a separate power supply.
12
Betriebsanleitung
Passiver DC-Signaltrenner SINEAX TI 807
Mode d'emploi
Séparateur galvanique passif
SINEAX TI 807
Operating manual
Passive DC signal isolator SINEAX TI 807
TI 807-1 B d-f-e
999 999
12.95
Aargauerstrasse 7
CH-5610 Wohlen/Switzerland
Telefon +41 56 618 21 11
Telefax +41 56 618 24 58
Telex 827 901 cbm ch

4. Specification and ordering information

Order Code 807 -
1. Mechanical design
Housing S17
2. Version
Standard (non-Ex)
Input and output signals
non-intrinsically safe
[EEx ib] II C,
Input signals intrinsically safe
[EEx ia] II C,
Output signals intrinsically safe
3. Number of isolation
and transmission channels
2 channels (interfaces)
3 channels (interfaces)
4. Output signals
A1 and A2 or A1, A2 and A3
0 ... 20 mA
0 ... 10 V, 2 channels
0 ... 10 V, 3 channels
5. Climatic rating
Standard climatic rating
Improved climatic rating

5. Technical data

Input signal E
DC current signal I
:
0...20 mA
E
Max. permissible
currnet:
50 mA
Non-Ex version: 27 V, ± 5%
Voltage limiter:
(with zener diode)
Ex version: 18 V, ± 5%
Output signal A
(DC current or DC voltage)
DC current signal I
:
0...20 mA
A
Voltage drop U
:
V
< 2.6 V
for the standard (non-Ex) version
< 4.5 V
for Ex versions
(input signals "intrinsically safe")
< 6.1 V
for Ex versions
(output signals "intrinsically safe")
Max. burden:
1000 Ω
for the standard (non-Ex) version
500 Ω
for Ex versions
(input signals "intrinsically safe")
500 Ω
for Ex versions
(output signals "intrinsically safe")
1
1
2
6
2
3
0
2
3
0
1

Publicité

Table des Matières