Software License Agreement - Garmin GFS 10 Instructions D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 7
To existing
CANet bus
(not included)
To ground (-)
Step 5: Update Your Chartplotter
To ensure compatibility with the GFS 10, upgrade your Garmin chartplotter with the latest software� For more information, visit www�garmin�com�
Specifications
Physical
Unit Dimensions:
2
/
in� (54 mm) W × 3
1
8
1
/
in� (32 mm) D
1
4
Weight:
14�8 oz� (420 g)
Cables:
Power/data cable - 25 ft� (7�6 m)
NMEA 2000 drop cable - 6 ft� (1�8 m)
Temperature range: From 5°F to 158°F (from -15°C to 70°C)
Case Material:
Fuel-resistant plastic
nMEa 2000 PGn Information
Transmit
ISO Acknowledgement
059392
ISO Address Claim
060928
Transmit/Receive PGN List Group Function
126464
NMEA–Command/Request/Acknowledge Group Function
126208
Product Information
126996
Engine Parameters–Dynamic
127489
Fluid Level (when calibrated on a Garmin chartplotter or instrument)
127505
Trip Parameters, Engine
127497

Software License agreement

BY USING THE GFS 10, YOU AGREE TO BE BOUND BY THE TERMS AND CONDITIONS OF THE FOLLOWING SOFTWARE LICENSE AGREEMENT� PLEASE READ THIS AGREEMENT
CAREFULLY�
Garmin grants you a limited license to use the software embedded in this device (the "Software") in binary executable form in the normal operation of the product� Title, ownership rights, and
intellectual property rights in and to the Software remain in Garmin�
You acknowledge that the Software is the property of Garmin and is protected under the United States of America copyright laws and international copyright treaties� You further acknowledge that
the structure, organization, and code of the Software are valuable trade secrets of Garmin and that the Software in source code form remains a valuable trade secret of Garmin� You agree not to
decompile, disassemble, modify, reverse assemble, reverse engineer, or reduce to human readable form the Software or any part thereof or create any derivative works based on the Software�
You agree not to export or re-export the Software to any country in violation of the export control laws of the United States of America�
4
Green
White
Bare
Black/White
Orange
Black/White
To power source/fuel gauge
Connecting the GFS 10 to a Canet Bus
/
in� (93 mm) H ×
21
32
CANet adapter
(included)
Power
Power input source:
10–22 Vdc
Fuse:
AGC/3AG - 0�25 A
Main power usage:
0�5 W max
nMEa 2000 power usage:
nMEa 2000 Load Equivalency number (LEn): 1
Flow
Max flow rate:
Min flow rate:
Max back pressure:
0�5 lb�/in�
Receive
ISO Acknowledgement
059392
ISO Request
059904
ISO Address Claim
060928
NMEA–Command/Request/Acknowledge Group Function
126208
The GFS 10 is NMEA 2000 certified�
GFS10
Drop cable
(built-in)
0�5 W max
50 gal�/hr� (190 L/h)
2 gal�/hr� (7�5 L/h)
at 20 gal�/hr�–1�0 lb�/in�
2
2
at 40 gal�/hr�
(3�4 kPa at 75 L/h–6�9 kPa at 150 L/h)
GFS 10 Fuel Sensor Installation Instructions

Publicité

Table des Matières
loading

Table des Matières