7 DEGREE MAX. ABOVE LEVEL
NOTE: IF UNIT IS INSTALLED UNLEVEL FRONT TO BACK, THE NOSE OR FRONT
15 DEGREE MAX. ABOVE LEVEL
NOTE: IF UNIT IS INSTALLED UNLEVEL FRONT TO BACK, THE NOSE OR FRONT
If the roof of the vehicle is sloped (not level) such
that the roof top air conditioner cannot be mounted
within the maximum allowable degree deviations, an
exterior leveling shim will need to be added to make
the roof top air conditioner level. A typical leveling
shim is shown in Figure 4.
OF THE UNIT MUST BE UP. DO NOT INSTALL NOSE DOWN.
ALLOWABLE OFFSET FOR ALL HEAT PUMPS WITH
RECIPROCATING COMPRESSORS.
FIGURE 2
OF THE UNIT MUST BE UP. DO NOT INSTALL NOSE DOWN.
ALLOWABLE OFFSET FOR ALL HEAT PUMPS
WITH ROTARY COMPRESSORS.
FIGURE 3
FIGURE 4
7 DEGREE MAX. ABOVE OR BELOW LEVEL
15 DEGREE MAX. ABOVE OR BELOW LEVEL
Height Varies To
Make Unit Level
E.
After the mounting hole area is properly
prepared, remove the carton and shipping pads
from the roof top air conditioner. Carefully
lift the unit to the top of the vehicle. Do not use
the outer plastic shroud for lifting. Place the
roof top air conditioner over the prepared mounting
hole. The pointed end (nose) of the shroud must
face towards the front of the vehicle. Pull the
electrical conduit down from the roof air
conditioner through the mounting opening and
let hang.
5