DOLD SAFEMASTER PRO Manuel D'utilisation page 52

Masquer les pouces Voir aussi pour SAFEMASTER PRO:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Acyclic data format
Errors data CPUx format
Name
Module
Error code
Error address
Firmware version (x.y in hexadecimal format)
Extended code 0 (optional)
Extended code 1 (optional)
The Module field is defined as follows:
B7-B2
Module name
The subfield Module name is defined as follows:
Name
UG6916.10
UG6912.02
UG6913.16
UG6913.08
UG6912.04
UG6913.12
UG6917/002
UG6917/x02
For the Error code field please refer to the SAFEMASTER PRO manual.
The optional Extended codes are only meaningful to DOLD
Input diagnostics format
Name
Diagnostic index
Diagnostic code
A maximum of 16 Input diagnostics are transfered, if more diagnostics are present on the system only the
first 16 are available on the fieldbus.
Output diagnostics format
Name
Diagnostic index
Diagnostic code
A maximum of 16 OSSD diagnostics are transfered, if more diagnostics are present on the system only the
first 16 are available on the fieldbus.
Project CRC format
Name
CRC byte 0
CRC byte 1
52
Système de sécurité configurable SAFEMASTER PRO - Modules bus de terrain
Code
2
3
4
5
6
7
8
9
Size
UINT8
UINT8
UINT32
UINT8
UINT8
UINT8
B1-B0
Node
Name
UG6917/xx2
UG6914.04/000
UG6914.04/008
UG6915/008
UG6915/016
UG6912.04/100
-
UG6916.12/080
Size
UINT8
UINT8
Size
UINT8
UINT8
Size
UINT8
UINT8
Code
10
11
12
13
14
15
16
17
0265999 / 16.05.19 fr / 101A