Please take note of the following:
• The recommended distance to any interfering sources like computer
monitors or TV sets is a minimum of 1.5 - 2 metres.
• Within ferro-concrete rooms (basements, superstructures), the
received signal is naturally weakened. In extreme cases, please place
the unit close to a window and/or point its front or back towards the
Frankfurt transmitter.
• During night-time, the atmospheric disturbances are usually less
severe and reception is possible in most cases. A single daily recep-
tion is adequate to keep the accuracy deviation under 1 second.
• The clock automatically scans the time signal at 2.00 a.m., 8.00 a.m.,
2.00 p.m. and 8 p.m. every day to maintain accurate timing. If the
reception is not successful, the DCF reception symbol disappears,
but the DCF time reception will be repeated again. The manually set
time will be overwritten by the DCF time when the signal is received
successfully.

6.3 Additional transmitters

• The wireless weather station can receive up to 3 temperature sen-
sors. If you have purchased additional transmitters, repeat step 1)
for all extra sensors. However, ensure that you leave 10 seconds in
between the reception of the last sensor and the set-up of the fol-
lowing sensor. The wireless weather station will number the sensors
in the order of set-up automatically.
7. How to operate
• The base station has three sections on the LCD: Time Mode, Indoor
Temperature & Humidity Mode and Outdoor temperature mode.
Press SET/MODE button to change between the sections (arrow).
• Press the +/CH button in time mode to select the display of time, cal-
endar (day-month-year) and alarm time.
• In outdoor temperature mode press +/CH button to toggle between
the outdoor sensor 1,2,3 (If more than 1 sensor is used)
• During operation, all successful settings will be confirmed by an
acoustical signal.
• The instrument will quit the setting mode, if there is no button used
within 30 seconds.

7.1 Setting Mode

• Press the SET/MODE button for 3 seconds while in normal mode to
enter the normal setting mode.
• In the setting modes, press +/CH button or -/MAX/MIN button to
select the units or scroll the value. Holding the buttons will
increase/decrease digits in great steps.
• Press the SET/MODE button to select the following setting in
sequence:
16
08.08.2016
15:34 Uhr
Seite 9
AXIS
– Wireless weather station
1. Time Zone Setting +-12 hrs.: The time zone is used for countries
where the DCF signal can be received but the time zone is dif-
ferent from the German time (e.g. + 1=one hour later).
2. 12/24 hour format
3. Manual time setting (hours/minutes)
4. Calendar setting(year /month/ day)
5. Temperature display unit degree Celsius or Fahrenheit
6. Pressure threshold setting (default 3hPa, see 7.4)
7.2 Alarm clock function
• Press twice +/CH button in normal mode. Alarm Time ("AL") appears
on the LCD.
• When viewing the Alarm Time, hold SET/MODE button for
3 seconds to enter Alarm Time setting. Press +/CH button or
-/MAX/MIN button to adjust the alarm time. Confirm hours with
SET/MODE button and switch to minutes setting. Confirm with
SET/MODE button.
• Press -/MAX/MIN button to switch alarm on or off. If it is on,
shown on the LCD.
• Press +/CH button to return to time mode.
• On the display appear the current time and the alarm symbol.
• Press any button to stop the alarm (120 sec).
• If the alarm is not stopped, the increasing alarm will automatically
turn off after 2 minutes and will be reactivated at the same time.
7.3 Min/Max Mode
7.3.1 Indoor Temperture & Humidity
• Press the SET/MODE button to make the arrow point to INDOOR
TEMPERATURE & HUMIDITY display section
• Press the -/MAX/MIN button to display the following values:
• Indoor temperature maximum
• Indoor temperature minimum
• Indoor humidity maximum
• Indoor humidity minimum
• Press the -/MAX/MIN button for 3 seconds, the above individual min-
imum or maximum record will be reset to zero.
7.3.2 Outdoor Temperature Mode
• Press the SET/MODE button to make the arrow point to OUTDOOR
TEMPERATURE display section.
• Press and release +/CH button to toggle between the outdoor sensor
1,2,3 (If more than 1 sensor is used)
• Press the -/MAX/MIN button to display the following values:
• Current channel outdoor temperature maximum
• Current channel outdoor temperature minimum
• Press the -/MAX/MIN button for 3 seconds, the above individual
minimum or maximum record will be reset to zero.