Inductive conductivity transmitter
Factory settings
Output mode
Conductivity range 1
Conductivity range 2
Conductivity range 3
Conductivity range 4

15. Configuration overview

15.1 Measurement ranges and basic principles
Temperature dependence
Medium
Acid
Base
Saline solution
Neutral water
Selectable conductivity ranges
0 ... 500 µS/cm
0 ... 1 mS/cm
0 ... 2 mS/cm
0 ... 3 mS/cm
Selectable concentration ranges
NaOH (caustic soda)
0 ... 12 % by weight (0 ... 90 °C)
20 ... 50 % by weight (0 ... 90 °C)
HNO
(nitric acid)
3
0 ... 25 % by weight (0 ... 80 °C)
36 ... 82 % by weight (0 ... 80 °C)
Customer defined media (30 point lookup table)
Settings for the external input for range selection
Range
S1
1
N.C.
2
24 V DC
3
N.C.
4
24 V DC
16 / 52
Conductivity measurement
Conductivity
0 ... 200 mS/cm
0 ... 20 mS/cm
0 ... 2 mS/cm
0 ... 500 µS/cm
% / K
1.0 ... 1.6
1.8 ... 2.2
2.2 ... 3.0
2.0
0 ... 5 mS/cm
0 ... 10 mS/cm
0 ... 20 mS/cm
0 ... 30 mS/cm
S2
N.C.
N.C.
24 V DC
24 V DC
Operating Instructions
Temperature output
Output damping
Temperature com-
pensation range 1–4
Lower output current
limit
Upper output current
limit
Sensor setting
Factory setting
Selectable range
0 ... 50 mS/cm
0 ... 100 mS/cm
0 ... 200 mS/cm
0 ... 300 mS/cm
0 ... 150 °C
0.0 s
2.0 % FSR/K
3.7 mA
21.0 mA
% / K
2.0
0.0 ... 5.0
0 ... 500 mS/cm
0 ... 1 S/cm
www.baumer.com

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Combilyz afi5