PERFORMANCE DATA SHEETS
Interior
Water
Filtration
System
Model OWF50-NI300
capacity 300 Gallons (1136 Liters)
Tested and Certified by' NSF International
against ANSt/NSF Standards
42 & 53 for the reduction of:
Standard No. 42: Aesthetic Effects
Taste & Odor Reduction
Chlorine Reduction
Mechanical Filtration Unit
Partictate Reduction Class 1
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead, Atrazine, Lindane & 2,4-D Reduction
Mechanical Filtration Unit
Cyst, Turbidity, & Asbestos Reduction
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances
listed below. The concentration
of
the indicated substances
in water entering the system was reduced to a concentration
less than or equal to the permissible
limit for
water leaving the system, as specified in ANSl/NSF 42/53. Systems certified for cyst reduction may be used on disinfected
water
that may contain filterable cysts.
Substance
Influent Challenge
Effluent Average
Average %
Max. Effluent
Min. Required
Inlet pH
Concentration
Reduction
Reduction
Lead:
0.15 mg/L _°_°
0.001 mg/L
99.33%
0.001 mg/L
0.010 mg/L
6.5
Lead:
0.15 mg/L _°_°
0.002 mg/L
98.66%
0.003 mg/L
0.010 mg/L
8.5
Cyst
Minimum 50,000 L
1 count/mL
99.99%
3 count/mL
> 99.95%
NA
Turbidity
11 __NTU
0.12 NTU
98.98%
0.18 NTU
0.5 NTU
NA
Lindane
0.002 mg/L _°_
0.00005 mg/L
97.62%
0.00005 mg/L
0.00002 mg/L
NA
Atrazine
0.009 mg/L _°_
0.0002 mg/L
97.93%
0.0006 mg/L
0.003 mg/L
NA
Chlorine
2.0 mg/L • _°_°
0.09 mg/L
95.26%
0.17 mg/L
S 75%
NA
Particulate*
at least 10,000 particles/mL
900 count/mL
99.68%
2400 count/mL
>_ 85%
NA
2,4-D
0.210 mg/L _1o_
45.45 ug/L
84.42%
100 ug/L
0.0017 mg/L
NA
Asbestos
107to 108 fibers/L; fibers greater
0.16 MFL/mL
99.96%
0.16 MFL/mL
99%
NA
than 10 micrometers
in length
* Particle size range classification
of test. Particles used were 0.5 - 1 microns.
Test Parameters: pH = 7.5 + 0.5 unless otherwise noted. Flow = 0.75 gpm (2.83 Lpm). Pressure = 120 psi (827 kPa). Temp. = 63°F
(17.2 °C).
•
It is essential that operational, maintenance,
and filter
•
replacement requirements be carried out for the product to
perform as advertised.
•
Using Replacement
Cartridge OWF51 - Model OWF50-
NI300: The concentration
of the indicated substances
in
water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the
system as specified in ANSl/NSF 42 and 53. Change
cartridge at least every 6-9 months. Use replacement
cartridge OWF51, part# 4396395.2003
suggested retail price
of $29.95 U.S.A./S39.95 Canada. Prices subject to change
without notice.
•
The product is for cold water use only.
•
Do not use with water that is microbiologically
unsafe or
of unknown quality without adequate disinfection before
or after the system.
•
Refer to the "Assistance or Service" section for parts and
service availability or for the Manufacturer's
name, address
and telephone number.
Refer to the "Warranty" section for the Manufacturer's
limited
warranty.
Note that while the testing was performed under standard
laboratory conditions, actual performance may vary. Systems
must be installed and operated in accordance with
manufacturer's
recommended
procedures and guidelines.
Application Guidelines/Water
Supply Parameters
Water Pressure
35 - 120 psig (241 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8 ° C)
Rated Service Flow
0.75 gpm (2.83 Lpm)
Pentapure Incorporated
1000 Apollo Road
Eagan, Minnesota 55121-2240
651-554-3141
® NSF is a registered trademark
of NSF International.
24