Design Information - Ge Monogram Zgu484Ngp5Ss Instructions D’installation

Table des Matières
Les langues disponibles

Les langues disponibles

Design Information
PRODUCT DIMENSIONS AND CLEARANCES FOR 48" MODELS
A WARNING:
Installations without a hood
require 48" minimum to combustibles
above the rangetop. A custom hood
installation with exposed horizontal
combustible surfaces must have
an Auto-On feature. Refer to hood
installation instructions for specific
hood clearances.
The surface of the entire back wall
above the countertop and below
the hood must be covered with
a non-combustible material such
as metal, ceramic tile, brick, marble
or other stone.
~
_
a7-te"to
Universal Utility Locations
@
Front of
>
Locate gas
" 17" |
inlet on back
wall or on
floor 2" from
back wall.
48" Minimum
to Combustibles
12" Minimum to
Adjacent Wall
\
i
12" Minimum
:
Each Side
se.
13" Max.
46-1/4" =~
22-3/4" Min.
* The opening between a 4" high backsplash must be 48"
to allow the rangetop to slide back against the wall.
12" Minimum to
Combustibles or 0" to
non-combustible
ADDITIONAL CLEARANCES:
material above the
each side.
48" Min. to
Combustibles
Working areas adjacent to the rangetop should have
18" minimum clearance between countertop and the
bottom of the wall cabinet.
Clearance
Table des Matières
loading

Ce manuel est également adapté pour:

Monogram zgu364ldp6ss

Table des Matières