Technical Specification Table; Instructions For Installation; Installation; Provisions Of The Law, Technical Rules And Regulations - Lotus Sv-11 Instructions D’installation Et D’utilisation

Table des Matières
Les langues disponibles

Les langues disponibles

MODELS
DIMENSIONS (cm)
20,5x41x22h
N. WATER
CONTAINER GN
POWER SUPPLY
CURRENT MAX.
POWER MAX.
CABLE (mm²)
The data plate is attached to the rear panel (see drawing under "electrical connection" ) and contains all the information
necessary for the connection.
When positioning the appliance make sure that it is perfectly level. Small adjustments can be made by screwing or
unscrewing the adjustable small feet. The main switch or the outlet must be in the vicinity of the appliance and easily
accessible. It is recommended to place the appliance under an extraction hood in order to rapidly eliminate vapour. If
the appliance is placed near walls or partitions, kitchen furniture, decorative coverings, etc. these must be flameproof or
coated with flameproof material. Above all, local fire prevention regulations must be observed.
During the installation a maximum distance must be respected between the front edge of the cabinet-support and the
appliance (see drawing under "emptying of the tub").
The installation must be carried out in accordance with the following standards:
-The accident prevention and electrical legislation in force.
-
Fire Department Regulations.
The installation, start-up and maintenance of this appliance must be carried out only by qualified personnel. All the
installation operations must be in accordance with the standards in force.
The manufacturer declines all responsibility for poor functioning due to incorrect installation or non-observance of the
regulations.
Warning: International provisions require that during the connection of the appliance there be a device which allows
the bi-polar disconnecting of the appliance from the network, upstream from the appliance. This device must have a
contact opening of at least 3 mm.
The appliance is supplied with the connection cable. If it has to be replaced proceed in the following manner:
- turn off the power.
- remove the rear panel
- disconnect the cable from the arrival terminal board which is found in the rear
part
- loosen the cable clip and extract the cable
- pass the new connection cable throught the cable clip, connect the wires in the
corresponding terminal of the terminal board and fix them
- lock the cable with the cable clip and reassemble the rear panel. The earth wire
must be longer that the others so in case the cable clip breaks, this disconnects
after the tension cables

TECHNICAL SPECIFICATION TABLE

SV-13
SV-12
29,5x41x22h
1GN1/3
1GN1/2
230VAC
230VAC
50Hz
50Hz
3,6A
3,6A
0,83KW
0,83KW
3X0,75
3X0,75

INSTRUCTIONS FOR INSTALLATION

INSTALLATION

Provisions of the law, technical rules and regulations

-

ELECTRICAL CONNECTION

GB
IE
SV-23
SV-11
38x41x22h
56x41x22h
1GN2/3
1GN1/1
230VAC
230VAC 50Hz
50Hz
5,2A
7,2A
1,19KW
1,66KW
3X0,75
3X1
-
Installation
17
SV-113
SV-123
73,5x41x22h
91x41x22h
1GN1/1
1GN1/1
+1GN1/3
+1GN2/3
230VAC 50Hz 230VAC 50Hz
10,8A
10,8A
2,49KW
2,49KW
3X1,5
3X1,5