Overload Protection; Overheat Protection; Main Power Switch - Makita MP001G Manuel D'instruction

Masquer les pouces Voir aussi pour MP001G:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

To install the battery cartridge, align the tongue on the
battery cartridge with the groove in the housing and slip
it into place. Insert it all the way until it locks in place
with a little click. If you can see the red indicator as
shown in the figure, it is not locked completely.
CAUTION:
Always install the battery cartridge
fully until the red indicator cannot be seen. If not,
it may accidentally fall out of the tool, causing injury to
you or someone around you.
CAUTION:
Do not install the battery cartridge
forcibly. If the cartridge does not slide in easily, it is
not being inserted correctly.
Indicating the remaining battery
capacity
Press the check button on the battery cartridge to indi-
cate the remaining battery capacity. The indicator lamps
light up for a few seconds.
► 1. Indicator lamps 2. Check button
Indicator lamps
Lighted
Off
NOTE: Depending on the conditions of use and the
ambient temperature, the indication may differ slightly
from the actual capacity.
NOTE: The first (far left) indicator lamp will blink when
the battery protection system works.
1
2
Remaining
capacity
Blinking
75% to 100%
50% to 75%
25% to 50%
0% to 25%
Charge the
battery.
The battery
may have
malfunctioned.
Tool / battery protection system
The tool is equipped with a tool/battery protection sys-
tem. This system automatically cuts off the power to
extend tool and battery life. The tool will automatically
stop during operation if the tool or battery is placed
under one of the following conditions:

Overload protection

This protection works when the tool/battery is operated
in a manner that causes it to draw an abnormally high
current. In this situation, turn the tool off and stop the
application that caused the tool to become overloaded.
Then turn the tool on to restart.

Overheat protection

This protection works when the tool/battery is over-
heated. The lamp blinks and the overheat warning icon
is displayed on the pressure gauge. In this situation,
turn the tool off and let the tool and battery cool down.
Then, turn the tool on again.
Overdischarge protection
This protection works when the remaining battery
capacity gets low. In this situation, remove the battery
from the tool and charge the battery.

Main power switch

WARNING:
Always turn off the main power
switch when not in use.
CAUTION:
When carrying the tool, turn off the
main power switch. Otherwise, pulling the switch
trigger unintentionally may cause an injury.
1
► 1. Main power switch
To turn on the tool, press the main power switch. To turn
off the tool, press the main power switch again.
NOTE: This tool employs the auto power-off function.
To avoid unintentional start up, the main power switch
will automatically shut down when the switch trigger
is not pulled for a certain period after the main power
switch is turned on.
6 ENGLISH

Publicité

Table des Matières
loading

Table des Matières