Portable Air Compressor
Table of Contents
Description . . . . . . . . . . . . . . . . . . . . . 1
Unpacking . . . . . . . . . . . . . . . . . . . . . . 1
Safety Guidelines . . . . . . . . . . . . . . . . 1
General Safety Information . . . . . . . . 1
Introduction . . . . . . . . . . . . . . . . . . . . 3
Assembly . . . . . . . . . . . . . . . . . . . . . . . 3
Operation . . . . . . . . . . . . . . . . . . . . . . 5
Maintenance . . . . . . . . . . . . . . . . . . . . 5
Troubleshooting Chart . . . . . . . . . . . . 6
Warranty . . . . . . . . . . . . . . . . . . . . . . . 8
Description
Air compressor units are intended
to provide compressed air to power
pneumatic tools and operate spray
guns . The pumps supplied are oil
lubricated . A small amount of oil
carryover is present in the compressed
air stream . Applications requiring air
free of oil or water should have the
appropriate filter installed . The air
compressor unit must be mounted
as described in the instructions on
a solid floor . Any other use of these
units will void the warranty and the
manufacturer will not be responsible
for problems or damages resulting from
such misuse .
Unpacking
After unpacking the unit, inspect
carefully for any damage that may
have occurred during transit . Make sure
to tighten fittings, bolts, etc ., before
putting unit into service .
Do not operate unit
if damaged during
shipping, handling or use. Damage may
result in bursting and cause injury or
property damage.
© 2010
ReAD & FOllOW All InSTRUCTIOnS
SAVe TheSe InSTRUCTIOnS

Safety Guidelines

This manual contains information
that is very important to know and
understand . This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS . To help
recognize this information, observe the
following symbols .
hazardous situation which, if not
avoided, WILL result in death or
serious injury.
hazardous situation which, if not
avoided, COULD result in death
or serious injury.
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
information, that if not followed,
may cause damage to equipment.
nOTe: Information that requires special
attention .

General Safety Information

CAlIFORnIA PROPOSITIOn 65
contain chemicals known to the State
of California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
DO nOT DISCARD
Danger indicates
an imminently
Warning indicates
a potentially
Caution indicates
a potentially
Notice indicates
important
This product or
its power cord may
VT6315, VT6358, VT6361
Breathable Air Warning
This compressor/pump is nOT
equipped and should nOT be
used "as is" to supply breathing
quality air. For any application of
air for human consumption, you
must fit the air compressor/pump
with suitable in-line safety and
alarm equipment. This additional
equipment is necessary to
properly filter and purify the air
to meet minimal specifications
for Grade D breathing as
described in Compressed
Gas Association Commodity
Specification G 7.1, OShA 29
CFR 1910. 134, and/or Canadian
Standards Associations (CSA).
DISClAIMeR OF WARRAnTIeS
In the event the compressor is
used for the purpose of breathing
air application and proper in-line
safety and alarm equipment
is not simultaneously used,
existing warranties are void, and
the manufacturer disclaims any
liability whatsoever for any loss,
personal injury or damage.
You can
create
dust when you cut, sand, drill
or grind materials such as
wood, paint, metal, concrete,
cement, or other masonry. This dust
often contains chemicals known to
cause cancer, birth defects, or other
reproductive harm. Wear protective
gear.
IN625501AV 8/10
Table des Matières
loading

Sommaire des Matières pour Campbell Hausfeld IN625501AV

  • Page 1: Table Des Matières

    Wear protective result in bursting and cause injury or Wash hands after handling. gear. property damage. REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. © 2010 IN625501AV 8/10...
  • Page 2: General Safety

    Operating Instructions General Safety Information Never Never operate attempt (Continued) compressor without a to repair or modify a tank! beltguard. This unit can Welding, drilling or any other GeneRAl SAFeTy start automatically without modification will weaken the Since the air compressor and other warning.
  • Page 3: Introduction

    VT6315, VT6358, VT6361 Operating Instructions Introduction Assembly ASMe Safety Valve - This valve automatically releases air if the tank Refer to Figure 1 to locate the following HANDLE ASSEMBLY - Handle may be pressure exceeds the preset maximum . items . pre-assembled on some units .
  • Page 4: Electrical Data

    Operating Instructions Assembly 4 . The length of copper wire between (Continued) Oil Fill Cap the outlet and circuit breaker is not (Dispose of BReATheR InSTAllATIOn properly) Dipstick longer than 40 feet of 14 AWG or 70 Breather Remove cap from oil fill opening . Install Breather feet of 12 AWG .
  • Page 5: Operation

    VT6315, VT6358, VT6361 Operating Instructions Operation Maintenance 8 . Attach hose, then add chuck or other tool to open end of hose . Plug START-UP in powercord . Turn pressure switch This compressor Disconnect, tag and lock out lever to AUTO position . When full pump must be filled power source, then release pressure is reached turn regulator...
  • Page 6: Troubleshooting Chart

    Operating Instructions Storage MAInTenAnCe SCheDUle 1 . When not in use, hose and OPeRATIOn DAIly Weekly MOnThly 3 MOnThS compressor should be stored in a CHECK OIL LEVEL cool dry place . DRAIN TANK 2 . Tanks should be drained of moisture . CHECK AIR FILTER and hose should be disconnected CHECK SAFETY VALVE...
  • Page 7: Corrective Action

    VT6315, VT6358, VT6361 Operating Instructions Troubleshooting Chart (Continued) Symptom Possible Cause(s) Corrective Action Large quanity of oil in 1 . Worn piston rings 1 . Replace with new rings . Maintain oil level and change oil more the discharge air frequently .
  • Page 8: Warranty

    A . Provide dated proof of purchase and maintenance records . B . Call Campbell Hausfeld (800-543-6400) to obtain your warranty service options . Freight costs must be borne by the purchaser . C . Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s) .
  • Page 9: Déballage

    Porter de l’équipement de Cette poussière contient souvent des protection. MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. 9 Fr © 2010 IN625501AV 8/10...
  • Page 10: Généralités Sur La Sécurité

    Instructions d’utilisation Généralités sur la Sécurité jamais jamais (Suite) utiliser un compresseur sans essayer de réparer ni de GÉnÉRAlITÉS SUR lA SÉCURITÉ carter de courroie. Ce modèle modifier un réservoir! peut se démarrer sans avis. Le soudage, perçage ou Puisque le compresseur d’air et les Le contact avec les pièces mobiles peut autre modifications peuvent affaiblir autres pièces détachées (pompe,...
  • Page 11: Introduction

    VT6315, VT6358, VT6361 Instructions d’utilisation Introduction Montage Soupape de Sûreté ASMe - Cette soupape laisse échapper l’air Se référer à la Figure 1 . MONTAGE DE MANCHE - La manche automatiquement si la pression du peut être pré-assemblée sur certains Manostat - Interrupteur Auto/OFF - réservoir dépasse la pression maximum appareils .
  • Page 12: Installation Du Reniflard

    Instructions d’utilisation Montage (Suite) Les modèles de 120 volts, 15 A peuvent Oil Fill Cap Bouchon (Dispose of fonctionner sur un circuit de 120 volts 15 (Éliminer properly) InSTAllATIOn DU RenIFlARD Reniflard de Dipstick correctement) A sous les conditions suivantes: Breather réglette- Breather...
  • Page 13: Démarrage

    VT6315, VT6358, VT6361 Instructions d’utilisation Montage (Suite) 5 . Tourner le bouton du régulateur soit utilisé dans le réservoir et que la complètement au sens contraire pression du réservoir atteint un niveau L’usage des aiguilles d’une montre . Le bas réglé d’avance, le manostat met le incorrect compresseur fonctionnera jusqu’à...
  • Page 14: Guide De Dépannage

    Instructions d’utilisation entretien (Suite) hORAIRe D’enTReTIen Une large quantité OPÉRATIOn qUOTIDIen heBDOMAD AIRe MenSUel 3 MOIS d’air sera relâchée rapidement si cette soupape est Vérifier le niveau actionnée lorsque le réservoir est d’huile pressurisé. Une large quantité d’air Purger le réservoir sera relâchée rapidement si cette soupape est actionnée lorsque le Vérifier le filtre...
  • Page 15: Guide De Dépannage (Suite)

    VT6315, VT6358, VT6361 Instructions d’utilisation Guide De Dépannage (Suite) Symptom Possible Cause(s) Corrective Action Bruit excessif 6 . Clapet bruyant dans le système 6 . Remplacer . (cognement) de compresseur Ne pas démonter le clapet si le réservoir (Suite) est pressurisé Large quantité...
  • Page 16: Garantie Limitée

    8 . RESPONSABILITÉS DE L’ACHETEUR AUX TERMES DE CETTE GARANTIE : A . Fournir une preuve d’achat datée et un état d’entretien . B . Appelez Campbell Hausfeld (800-543-6400) pour obtenir vos options de service sous garantie . Les frais de transport sont la responsabilité de l’acheteur .
  • Page 17: Déballage

    Use equipo de nO lAS DeSeChe puede producir polvo. Con frecuencia protección. RECORDATORIO: ¡Guarde su comprobante de compra con fecha para fines de la garantía! Adjúntela a este manual o archívela en lugar seguro. 17 Sp © 2010 IN625501AV 8/10...
  • Page 18: Informaciones Generales

    Manual de Instrucciones de Operación Informaciones Generales de Nunca Nunca use tuberías opere el de plástico (PVC) Seguridad (Continuación) compresor sin las tapas de en sistemas de aire comprimido. El protección. Esta unidad se compresor sin las tapas de protección. GeneRAleS SeGURIDAD puede encender El hacerlo podría ocasionarle heridas o...
  • Page 19: Introducción

    VT6315, VT6358, VT6361 Manual de Instrucciones de Operación Introducción ensamblaje Válvula de Seguridad ASMe - Esta válvula libera el aire automáticamente Vea la Figura 1a ó 1b . ENSAMBLADO DEL MANGO - El mango si la presión del tanque excede el nivel puede venir ensamblado previamente Presostato - Sistema de encendido máximo fijado .
  • Page 20: Datos Eléctricos

    Manual de Instrucciones de Operación ensamblaje 1 . No haya ningún otro artefacto (Continuación) Oil Fill Cap El tapón (Desechar (Dispose of eléctrico o luces conectados al mismo apropiadamente) properly) InSTAlACIÓn Del ReSPIRADeRO Reniflard de Dipstick circuito . Breather réglette- Breather Retire el tapón del orificio para llenar Respiradero...
  • Page 21: Funcionamiento

    VT6315, VT6358, VT6361 Manual de Instrucciones de Operación ensamblaje Mantenimiento 5 . Gire la perilla del regulador (Continuación) completamente en el sentido contrario a las agujas del reloj . El compresor alcanzará la presión Desconecte el cordón El uso inadecuado del eléctrico y amárrelo y máxima fijada y se apagará...
  • Page 22: Guía De Diagnóstico De Averías

    Manual de Instrucciones de Operación Mantenimiento Almacenamiento (Continuación) TORqUE REqUERIDO (kg/cm) 2 . Con el motor APAGADO y 1 . Cuendo no los esté usando, Pernos desconectado, limpie el motor, el almacene la manguera y el Pernos del de los volante, el tanque, las líneas de compresor en un sitio frío y seco .
  • Page 23 VT6315, VT6358, VT6361 Manual de Instrucciones de Operación Guía de Diagnóstico de Averías (Continuación) Problema Posible(s) Causa(s) Acción a Tomar Ruido excesivo (golpeteo) 6 . Válvula de verificación ruidosa en 6 . Reemplácela . (Continuación) el sistema del compresor No desarme la válvula de verificación con presión de aire en el tanque.
  • Page 24: Garantía Limitada

    A . Suministrar prueba fechada de compra y la historia de mantenimiento del producto . B . Entregar o enviar los compresores de aire portátiles o componentes lal Centro de Servicio autorizado Campbell Hausfeld más cercano . Los gastos de flete, de haberlos, deben ser pagados por el comprador .

Table des Matières