Electrical Supply
The customer has the responsibility of ensuring that the dishwasher electri-
cal installation is in compliance with all national and local electrical codes
and ordinances. The dishwasher is designed for an electrical supply of
120V, 60 Hz, AC, connected to a dishwasher-dedicated, properly grounded
electrical circuit with a fuse or breaker rated for 15 or 20 amps.
Dishwasher Electrical Rating
Grounding Instructions
The dishwasher must be properly grounded before operating. This appli-
ance must be connected to a grounded metal permanent wiring system
or an equipment grounding conductor must be run with the circuit con-
ductors and connected to the equipment grounding terminal or lead on
the dishwasher.
Do NOT use an extension cord.
Make sure that the dishwasher is connected to a suitable ground in
compliance with all local codes or, in the absence of a local code, with
the NATIONAL ELECTRICAL CODE in the United States or the CANADIAN
ELECTRIC CODE C22.1-latest edition in Canada as well as any provincial/
state or municipal or local codes that apply.
Note: Installations requiring hard wiring and terminal block - The
accessory terminal block/junction box model, SMZPCJB1UC, designed
for permanent wire connection, is not included but can be ordered
through Customer Service by calling 1-800-944-2904. Follow the
instructions included with the kit.
Volts Hertz
120
60
Amperes
Watts
12
1,440
(max)
15