CDVI CAA Manuel D'installation page 16

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
CAA - CBB
Self-contained Keypads - braille keys
3. Press
5 to change the master code.
- Green LED lights on for 1 second.
- Enter the 4, 5 or 6 digits of the new
master code.
- The green LED lights on during 1 second
to confirm the new master code.
You MUST change the master code
before you exit from programming
if you have changed the digit length
4. Press # to exit from the programming
mode.
The red LED lights off to confirm that the keypad
is in stand-by operating mode.
Red LED flashing 4 times indicates
a data computing error.
C. Programming a New Master Code
1. Enter the master code twice.
- For the first use, the factory
master code is: 1 2 3 4 5.
- Red LED lights on to confirm
entry in programming mode.
2. Press
5 to program the master code.
- Green LED lights on for 1 second.
- Enter 4, 5 or 6 for number of digits.
- Press
and # to confirm
- The green LED lights on for 1 second
to confirm the new master code.
3. Press # to exit from the programming mode.
The red LED lights off to confirm that the keypad
is in stand-by operating mode.
D. Adding, changing or deleting
a user code
Relay 1
Group 1: From location 00 to location 59,
Relay 2
Group 2: From location 60 to location 79.
Relay 3
Group 3: From location 80 to location 99.
cdvi.com
16
cdvigroup.com
Master code
Master code
1. Enter the master code twice.
- For the first use the factory master code
is: 1 2 3 4 5.
- The red LED's light on to confirm entry
in programming mode.
2. Enter the user location to be programmed
(from 00 to 99).
- If the location is free, the green LED's light on
during 1 second, enter the 4, 5 or 6 digits of the
code.
- If the location is occupied, the red LED's flashes
4 times.
- Enter the 4, 5 or 6 digits of the code
or enter 0 0 0 0 0 0 or 0 0 0 0 0 or 0 0 0 0
to cancel the existing code.
- If the Pin code is already programmed
or is identical to the master code,
then 4 beeps are emitted.
- Codes 0 0 0 0 0 0 or 0 0 0 0 0
or 0 0 0 0 serve to cancel an existing
code and hence cannot be used
as an usual code.
3. Press # to exit from the programming mode.
The red LED lights off to confirm that the keypad
is in stand-by operating mode.
E. Time outputs
1. Enter the master code twice.
- For the first use, the factory
master code is: 1 2 3 4 5.
- Red LED lights on to confirm entry
in programming mode.
2. Enter
0 for the key-in keypad time.
- Green LED lights on for 1 second.
- Enter the duration time in second
E.g. : From 10 for 10 seconds to 99
for 99 seconds
- The green led lights on to confirm
the programming.
3. Press
1 for output time of relay 1
- Green LED lights on for 1 second.
- Enter the duration in seconds.
E.g. : From 01 for 1 second to 99
for 99 seconds or enter 00 for a permanent
EN