4.
New press F knob (9) to validate. The parameter stops blinking. a) Go to
point 1 to
adjust
another function or b) Press the PTT switch (13) to
and
exit
MENU.
disappears.
5.
If no key is pressed, the unit
exits
the display.
Default ROGER BEEP is Of.
5) SWR ADJUSTMENT
This function allows to adjust the SWR (Standing Wave Ratio) by beep tones.
Press F knob (9) to
enter
MENU.
1.
Turn the rotary CH knob (3) or use the UP/DN buttons (14) on the microphone
to
select
the SWR function.
2.
Press the F knob (9). The radio automatically goes to
pressing PTT switch (13) . The SWR measurement starts. Measurement time
is 5 minutes maximum. The remaining time is displayed.
3.
Adjust your antenna.
4.
The beep tone* is continuous when SWR value is equal to1. 0 . The space
between two beeps became longer when SWR value moves away from1. 0 .
Volume of the beep tone is adjustable with VOLUME knob (1).
Display shows the SWR value. For example 2. 5 .
5.
Press PTT switch (13) to
exit
MENU mode.
*Please check that the beep volume is set to a comfortable listening level.
See § HOW TO ADJUST SWR page 34.
6) EMG SET 1
Allows to
set
the channel and mode for Priority Channel 1.
Press F knob (9) to
enter
MENU.
1.
Turn the rotary CH knob (3) or use UP/DN buttons (14) on the microphone
select
to
the EMG 1 function.
2.
Press F knob (9) to
validate.
The first parameter, channel blinks on LCD.
3.
Turn the rotary CH knob (3) or use UP/DN buttons (14) on the microphone
to
select
the channel.
4.
New press F knob (9) to
validate.
parameter, mode blinks on LCD.
5.
Turn the rotary CH knob (3) or use UP/DN buttons (14) on the microphone
select
the mode AM, FM or FM UK (only in U configuration).
to
6.
New press F knob (9) to validate. The mode stops blinking. a) Go to point
1 to
adjust
another function or b) Press the PTT switch (13) to
exit
MENU.
disappears.
7.
If no key is pressed, the unit
exits
the display.
validate
MENU after 10 seconds,
disappears in
is displayed.
TX
mode without
disappears in the display.
is displayed.
The channel stops blinking. The second
validate
MENU after 10 seconds,
disappears in
Default Priority channel 1 is 9/AM.
See § PRIORITY CHANNELS page 36.
7) EMG SET 2
Allows to set en the channel and mode for Priority Channel 2.
Press F knob (9) to
enter
1.
Turn the rotary CH knob (3) or use UP/DN buttons (14) on the microphone
select
to
the EMG 2 function.
Points 2 to 7 are identical to § EMG SET 1.
Default Priority channel 2 is 19/AM.
See § PRIORITY CHANNELS page 36.
8) VOX SET
Press F knob (9) to
enter
1.
Turn the rotary CH knob (3) or use UP/DN buttons (14) on the microphone
to
select
the VOX function.
Three adjustments are possible: Sensitivity L / Anti-vox level A / Vox delay time
t (Loop in this order).
2.
Press F knob (9). The current setting (L, A or t) blinks on the LCD.
3.
Turn the rotary CH knob (3) or press the UP/DN (14) buttons on the microphone
to
move
to next setting.
4.
Press F knob (9). The value of the current setting blinks on the LCD.
5.
Turn the rotary CH knob (3) or press the UP/DN (14) buttons on the microphone
to
adjust
the setting.
6.
Press F knob (9) to
store
7.
Go to point 2 to set two others adjustments of VOX.
8.
Once the settings have been made, press the PTT switch (13) to
VOX Adjustment mode. If no adjustment is made for 10 seconds, the unit
automatically exits the function.
-
Sensitivity L: allows the adjustment of the microphone (original one or
optional vox) for an optimum transmission quality. Adjustable level from1
(high level) to 9 (low level).Default value: 5.
-
Anti-Vox A: allows disabling the transmission generated by the surrounding
noise. The level is adjustable. OF (according the squelch level) and from 0
(without anti-vox) to 9 (low level). Default value: OF.
Delay time t: allows avoiding the sudden cut of the transmission by adding
-
a delay at the end of speaking. The level is adjustable from 1 (short delay)
and
to 9 (long delay). Default value: 1.
9) PA SETTING
39
https://manual-hub.com/
MENU.
is displayed.
MENU.
is displayed.
validate
and
the setting
exit
the