Switching On And Turning Off; Setpoint Setting; Manual Defrosting - Studio 54 OASIS 600 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5
Defrost Led
6
Alarm Led
7
STAND-BY (ESC)
8
SET

13. Switching on and turning off

To turn the refrigerator on it is sufficient to activate the switch in the ON position with green light on.
The display will flash for 3 seconds, then it will report the temperature inside the cell and begin the
cycle refrigerator. During the course of this operation, the display you will show the LED light near the
snowflake (No. 5) and the LED light of the internal fan. (# 4)
To turn the refrigerator off it is sufficient to activate the switch in the OFF position with green light off.

13.1 Setpoint setting

To display the setpoint value press the 8 key: "set" will appear. Pressing again the 8 key it will be
shown the default value of the setpoint on the display. To change the setpoint value act on the 1 and 2
keys within 15 seconds. To confirm the change, press the 10 key.
With setpoint it is meant a temperature value to be achieved from the food with a tolerance of 2°C
higher

13.2 Manual defrosting

To activate manual defrost it is sufficient to hold the 1 key for 5 seconds, then all the led will turn off
and it will light up the LED No. 5 and it will begin the defrost cycle
TROUBLESHOOTING
LABEL
TROUBLE
Probe 1 broken
E1
(cell)
Probe 2 broken
E2
(defrosting)
HIGH alarm
AH1
Temp. probe 1
Steady: defrost activated
Flashing: manual activation
Steady: presence of an alarm
Flashing: alarm
Press and release Goes up one level from the current menu
Confirmation parameter value
Press for at least 5 seconds Activates the stand-by function
(when not inside the menu)
Press and release Displays alarms (if present)
Accesses to Basic Commands Menu
CAUSE
• reading of
values outside of
the range of
operation
• broken probe /
short-circuit / door
open
• reading of
values outside of
the range of
operation
• broken probe /
short-circuit / door
open
Fridge
temperature too
much elevated
RESULT
•Label E1
•Steady Alarm Icon
•Label E2
•Steady Alarm Icon
•The defrosting cycle
will end for time-out
•No effects on
regulation
SOLUTION
•Check probe type
(NTC)
•Check probes wiring
• Substitute the probe
•Check probe type
(NTC)
•Check probes wiring
•Substitute the probe
Wait the temperature
value red from probe 1
goes down of HAL.