Dim 6 : DMX 512
MEMORACK is a dimmer unit designed to be rack-mounted in a
fixed installation or flight-case.
MEMORACK belongs to class I equipment and requires a safety
earth connection in compliance with local regulations. It is a
professional digital dimmer, built in accordance with European
safety standards EN 60950 and EN 60204.
MEMORACK has been designed to supply luminaires.
Lethal voltages are present inside. Access to internal parts is not
required for normal operation.
Refer servicing to qualified personnel. Always disconnect from the
mains supply before removing the cover.
Always use original spare parts (fuses, etc.)

Supply Connections

Type of mains supply network
Before you connect electrical equipment, you must verify that it is
adapted to the mains system at your venue. If in doubt consult the
electrician or the utility company.
Protection on the supply side
The power outlet and the supply cable which feed the MEMORACK
must be adequately protected against overload and short-circuit by the
installation; verify the applicable wiring regulations.
Supply Connection
MEMORACK 15
: inlet CEE 32 A (P17), cable optional
MEMORACK 30
: inlet HARTING 4 x 80 A + PE
Supply cable
The size of the Neutral wire must at least be equal to the size of the
phases; reduced-size Neutral wires are DANGEROUS and are NOT
allowed. All supply cables and extension cables should have all
conductors under the same sleeve, in order to reduce unwanted
interferences to audio and video equipment.
The supply cable should be sized for the rating of the MEMORACK:
27 A per phase for three-phase star operation (3 x 400 V + N);
, EPR insulation, 85 °C for MEMORACK 15
e.g. cable 5 x 4 mm
2
50 A per phase for three-phase operation (3 x 400V + N);
, EPR insulation, 85 °C for MEMORACK 30
2
e.g. cable 5 x 10 mm
Cables for lower current ratings are only allowed if the protection
devices in the supply installation (supply fuses or supply circuit-breaker)
are selected accordingly.
Spade terminals11 suitable for cables up to 10 mm
single-phase conversion kit.
Use of MENU
Your MEMORACK can be programmed by means of three different
menus, for 4 levels of application:
Menu 0 displays the DMX address and Patch INFO, without access
to modifications
Menu 1 opens up one function: set the DMX address
Menu 2 provides more advanced functions
Menu 3 is the Maintenance Menu
Menu 1 set in the factory, and by the Clear More function.
If you select a different Menu Level, then your selection will also be
maintained after power-up.
Lighting Technologies
How to modify the DMX addresses
Example :
If you wish to use one of the following functions, then you should open
up Menu 2:
How to select Menu 2
The triple YES will protect against tampering. In Menu 2 you have
access to more advanced functions than in Menu 1.
To display the list of functions available in Menu 2:
How to modify the address for one dimmer (patch)
Example:
How to display the current patch (Info)
While setting a parameter for one dimmer, e.g. dimmer law, the INFO
function will instantly display the DMX address.
How to test one dimmer (Test)
2
Test controls one single dimmer, at a preset level of 70%, or at the level
are included in the
of your choice. All other dimmers are Off.
Example:
How to flash one dimmer (Flash)
Flash is similar to Test, but the dimmer will flash at a preset level of 70%.
All other dimmers are Off. Very useful to find a dimmer in a rig.
Subject to modification. Complete manual on request
MEMORACK 15
MEMORACK 30
to set the start address to 31, so that dimmer No. 1 is
31, No. 2 is 32, No. 3 is 33,...
depress + or - until
Addr. (...) ?
depress + or - until
Dim 1 DMX 31
If a patch was programmed previously,
the display will show :
Erase Patch?
depress
YES
if you agree to erase that patch
depress
<—
if you want to save the old patch
Patch
select the DMX address for each dimmer
Test a dimmer
test one dimmer, at the level of your choice
Test Chaser
run a chaser through all dimmers
Flash
flash one dimmer, to find it in a rig
Law
set the dimmer law, per dimmer
Mult. factor
set a proportional factor, per dimmer
Memories
use the local memories (cues)
View DMX
DMX tester: display DMX levels
View Analogue
Analogue tester: display Analogue levels
depress + or - until
Menu Level ?
depress + or - until
Menu Level : 2
depress +
do not depress the YES key
you wish to set dimmer No. 2 to address 120
select Menu 2, as indicated above
depress + or - until
Patch ?
the display shows
Dim 1 : DMX ...
depress + or - until
Dim 2 : DMX ...
depress + or - until
Dim 2 : DMX 120
depress <— to return to main Menu
At any position in any menu item :
depress INFO
depress + or - to view the addresses
to quit: depress INFO or wait for three seconds
to test dimmer 3 at 70%
select Menu 2, as indicated above
depress + or - until
Test a dim ?
depress + until
Test 3:70%
the display shows
Test 3:70%
depress + or - to modify the dimmer level
depress <— to end dimmer test and <— to return to main Menu
depress
YES
depress
YES
depress YES
depress 3 x YES
depress
YES
depress
YES
depress
YES
depress
YES
depress
YES
dim. No 3 is now
on, at 70%
7