Characteristics Table - BALAY 3XP 20 Série Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Models
Performance
Maximum cooling capacity (
Maximum consumption: cooling
Maximum consumption: heating
Dehumidification capacity
Fuse
Sound level (min/max)
Refrigerant
Maximum air flows
Cooling
Ventilation
Heating
Operation range
Cooling (min/max)
Dehumidification (min/max)
Heating (nim/max)
Size
Height of the unit
Width of the unit
Depth of the unit
Weight of the unit
Length of cable
Length of drainage pipe
Accessories
Window accessory RKZ 1000
Balcony accessory RKZ 2000
Wall/window tube B1 RKZ 06009
Set of active filters RKZ 09013
*
(
) ASHRAE 128

Characteristics Table

*
)
watts
watts
watts
l/24h
dB(a)
3XP 20.. 3XP 22.. B 3XP 22..
2.300
955
-
26
A
10
45/48
R-407C
m
3
215
3
m
275
m
3
-
°C
20/35
°C
18/35
°C
-
cm
86,5
cm
43,8
cm
43,5
kg
32
cm
210
cm
140
X
X
X
X
38
2.500
2.600
1.200
2.000
30
10
46/49
45/48
R-410A
R-410A
180
220
220
20/35
20/35
18/35
18/35
unlimited/30
86,5
43,8
43,5
32
210
140
X
X
X
X
1.200
-
30
10
215
275
-
-
86,5
43,8
43,5
32
210
140
X
X
X
X

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

3xp 22 série3xp 22 b série

Table des Matières