Connecting A Consumer; Servicing And Cleaning - VOLTCRAFT 51 13 60 Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

• If, on the other hand, the red display "N" (3) lights up, you have to turn the mains
plug 180° in the socket (wall socket). This is an additional protective measure to
prevent risks when defective devices are connected.
If both signal displays light up, this is indication of a missing earth
wire. Do not put the series transformer into operation and have
the mains socket checked by a specialist. In case of error, a bro-
ken earthing wire can be fatal!

Connecting a consumer

Independent of the selection of input voltage, the following output voltages are
always pending at the output sockets:
• earthing socket (1) optionally 115V~ / 125V~ / 230V~ / 240V~ (adjustable by means
of the voltage selection switch (6); use a suitable screwdriver for the change-over)
• US earthing socket (5) 115V~ not adjustable
Connect your consumer to the appropriate output socket (1 or 5) using a suitable
mains cable.
Make sure that the insulation of the mains cables is not damaged.
Make sure that the consumers are switched off when being
connected to the series transformer. Sparks may be generated
when a switched-on consumer is connected to the jacks. This
may damage the terminal screw connectors as well as the
connected cables.
If the series transformer is no longer required, disconnect it from
the mains.
During a longer period of operation under nominal load, the surfa-
ce of the housing will heat up. Therefore, make sure that there is
adequate ventilation of the device and, to avoid any damage,
never operate it when partly or completely covered.

Servicing and cleaning

The devices are maintenance-free apart from the replacement of fuses and occasio-
nal cleaning. To clean the device, switch of the power and take a clean, lint-free, anti-
static and dry cloth without any abrasive or chemical agents or detergents contai-
ning solvents.