Télécharger Imprimer la page
Les langues disponibles

Les langues disponibles

PC50XP INSTALLATION, OPERATION,
AND MAINTENANCE MANUAL
INTRODUCTION
DO NOT INSTALL, USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND UNDERSTOOD. READ AND SAVE
THESE INSTRUCTIONS FOR FUTURE USE.
These instructions are intended to supplement sound installation practices and are not intended to cover detailed instruction procedures
because of the wide variety of fan types and field conditions that exist.
It is the responsibility of the purchaser to assure that the installation and maintenance of this equipment is handled by qualified personnel
experienced in such work and equipment.
Contact your local representative should you need further information.
SAFETY INFORMATION
WARNING! To reduce the risk of fire, electric shock, or injury to persons, observe the following:
a. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
b. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being
switching on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a
tag, to the service panel.
c. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
d. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
e. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
f. Ducted fans must always be vented to the outdoors.
g. Acceptable for use over a tub or shower when connected to a GFCI (ground fault circuit interrupter)—protected branch circuit (ceiling
installation only).
h. This unit must be grounded.
i. Not for use in kitchens.
j. To reduce risk of fire and to properly exhaust air, be sure to duct air outside—do not vent exhaust air into spaces within walls/ceilings or into
attics, crawl spaces, or garages.
®
S & P V E N T I L AT I O N SYS T E M S
S o l er Pal a u- USA . co m | S o l erPa l a uC a n a d a .c o m
®
loading

Sommaire des Matières pour S&P PC50XP

  • Page 1 ® S & P V E N T I L AT I O N SYS T E M S PC50XP INSTALLATION, OPERATION, AND MAINTENANCE MANUAL S o l er Pal a u- USA . co m | S o l erPa l a uC a n a d a .c o m INTRODUCTION DO NOT INSTALL, USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND UNDERSTOOD.
  • Page 2 CAUTION 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. This product is designed for installation in ceilings up to a 12/12 pitch (45° angle). Duct connector must point up. 3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 4.
  • Page 3 2. Housing mounted between joists: a. Slide one hanger bar into the channel on the housing and adjust as needed to fit in between the framing. b. Hold housing in place so that the housing contacts the bottom of the joist, screw the housing to the joist through the hole of the housing.
  • Page 4 RETROFIT INSTALLATION Blower assembly 1. Remove wire panel and blower assembly before installation. Wire panel 2. Fold mounting ears flat against housing. 9-1/2” 3. Enlarge ceiling opening to 9-1/2" by 9-1/2", leave ductwork and wiring in place. 4. Connect wiring according to the wiring diagram.Re-install wire panel. 9-1/2”...
  • Page 5 INSTALL GRILLE Install ceiling material to complete the ceiling construction. Then, cut around the fan housing. To attach the grille assembly to the fan housing, pinch the grille springs on the sides of the grille assembly, and position the grille into the housing with the grille springs in the appropriate slots.
  • Page 6: Fonctionnement Et Entretien

    PC50XP INSTALLATION, FONC TIONNEMENT E T ENTRE TIEN INTRODUCTION N’INSTALLEZ PAS, N’UTILISEZ PAS OU N’UTILISEZ PAS CET ÉQUIPEMENT AVANT D’AVOIR LU ET COMPRIS CE MANUEL. LISEZ ET CONSERVEZ CES INSTRUCTIONS POUR UNE UTILISATION ULTÉRIEURE. Ces instructions visent à compléter les saines pratiques d’installation et ne visent pas à couvrir les procédures d’instruction détaillées en raison de la grande variété...
  • Page 7: Fonctionnement

    NETTOYAGE ET ENTRETIEN Pour un fonctionnement silencieux et efficace, une longue durée de vie et un aspect attrayant - en dévissant la plaque de recouvrement, aspirer l’intérieur de l’appareil à l’aide de la brosse à épousseter. Le moteur est lubrifié en permanence et n’a jamais besoin d’être huilé. Si les roulements du moteur font des bruits excessifs ou inhabituels, remplacez le moteur par un moteur de service identique.
  • Page 8 2. Boîtier monté entre les solives: a. Glissez une barre de suspension dans le canal du boîtier et ajustez-la si nécessaire pour qu’elle s’insère dans l’encadrement. b. Maintenez le boîtier en place de manière à ce qu’il soit en contact avec le bas de la solive, puis vissez le boîtier à...
  • Page 9 INSTALLATION DE MODERNISATION Blower assembly 1. Retirer le panneau de câblage et le ventilateur avant l’installation. Wire panel 2. Replier les oreilles de montage à plat contre le boîtier. 9-1/2” 3. Agrandir l’ouverture du plafond à 9-1/2" par 9-1/2", laisser les conduits et les câbles en place.
  • Page 10: Garantie

    INSTALLER LA GRILLE Installez le matériel de plafond pour compléter la construction du plafond. Découpez ensuite autour du boîtier du ventilateur. Pour fixer la grille au boîtier du ventilateur, pincez les ressorts de la grille sur les côtés de la grille et placez la grille dans le boîtier avec les ressorts de la grille dans les fentes appropriées.
  • Page 11 S&P VENTILATION SYSTEMS Enab ling the World t o Bre athe B et ter Air ® S&P USA VENTIL ATION SYSTEMS, LLC S&P CANADA VENTILATION PRODUCTS, INC. 6393 Powers Avenue 6710 Maritz Drive, Unit 7 Jacksonville, FL 32217 Mississauga, ON L5W 0A1, Canada SolerPalau-USA.com SolerPalauCanada.com 800.961.7370...